EasyManua.ls Logo

Airo SF series - 7.2.12 Starter Type Battery for Models D E;D; 7.2.12.1 Starter Battery Maintenance; 7.2.12.2 Starter Battery Recharge

Airo SF series
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Use and maintenance manual Self-propelled aerial platforms Page 55
7.2.12 Starter type battery for models “D” “E/D”
On machines with heat engine the starter battery is for:
- Powering the machine control circuits;
- Starting the heat engine.
7.2.12.1 Starter battery maintenance
The starter battery does not require any maintenance operation.
- Keep terminals clean by removing any oxidation residues;
- Check correct terminal tightening.
7.2.12.2 Starter battery recharge
Starter batteries do not require any recharge.
During normal operation of the Diesel engine an alternator recharges the battery (machines D”, “E/D”). On those machines
equipped with a 380 three-phase electric pump, the electric pump control system keeps the starter battery charged.
CAUTION!
Check the charge of the starter battery after carrying out a recovery operation of the platform with the
emergency electric pump (OPTIONAL).
7.2.13 Battery replacement
Replace the old batteries only with models of the same voltage, capacity, dimensions and mass.
Batteries must be approved by the manufacturer.
AS THIS OPERATION IS VERY IMPORTANT IT IS TO BE CARRIED OUT BY SPECIALIZED TECHNICIANS ONLY.
CALL THE TECHNICAL SUPPORT

Table of Contents