18. If EC does not
function correctly:
Check first:
- Fogger runs correctly so there is sufficient air
pressure to open EC.
18. EC funktioniert nicht
ordnungsgemäß:
Vorabkontrollen:
- Nebelgerät läuft ordnungsgemäß, der
Luftdruck reicht also zum Öffnen der EC aus.
Possible causes: Check:
Mögliche Ursachen:
Folgende Punkte kontrollieren:
- incorrect setting of screw
type nipple (EC25) at the
Bowden cable (EC23) -
piston (EC8) is not pushed
back into initial position. -
spring (EC9) too weak or
broken
- the diaphragm (EC6) of
the pressure cell is
damaged or dirty
- incorrect setting of screw
type nipple (EC25) at the
Bowden cable (EC23) -
piston (EC8) is not pushed
forward
- spring (EC9) too strong
- the diaphragm (EC6) of
the pressure cell is
damaged or dirty
- leak of pressure in the
“EC” system
- clog of air pressure
tube (EC20)
- incorrect setting of screw
type nipple (EC25) at the
Bowden cable (EC23) -
spring (EC28) too weak or
broken
- damage of o-ring (EC32) -
valve housing (EC33) dirty
- Nebelgerät stoppt,
Bedienhebel wird
nicht automatisch
ausgerückt
- Motor des
Nebelgeräts läuft,
aber Hebel kann
nicht eingerückt
werden
- Nebelgerät in
Betrieb und Hebel
wird ausgerückt,
Vernebelung stoppt
nicht
- fogger stops,
operating lever does
not release
automatically
- fogger engine runs
but lever can not
engage
- fogger in operation
and lever releases,
fog does not stop