EasyManua.ls Logo

Airrex HSC-60P - User Manual

Default Icon
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
It is essential that you read ‘SAFETY INSTRUCTIONS’ carefully
before use and follow them at all times.
We have a policy of continual improving on our products.
The contents (features and specifications) in this manual are
therefore subject to change without notice.
The warranty form is on the last page. Please complete it
now and keep it in a safe place.
Keep this manual on hand for reference.
Thank you for purchasing the unit.
Before operation, please read this user’s manual carefully.
MODEL : AHSC-140P 220/3
USER'S MANUAL
AIR CONDITIONER
WITH ELECTRIC HEAT
▶ This unit is specified for use on the rated voltage
power supply.
C

Questions and Answers

Summary

Safety Instructions and Precautions

Operational Warnings

Safety warnings and precautions for operation.

Installation Guidelines

Guidelines for unit installation, placement, and moving.

Usage Cautions

Cautionary notes and advice for safe use and storage.

Product Specifications

Control Panel Functions Overview

Mode Changing Method

How to Set the Off Timer

Temperature Control Operation

Error and Warning Indicators

Error Codes E1-E5

Details on error codes E1 through E5: problems, causes, and corrective actions.

Error Codes E6-OH

Details on error codes E6 through OH: problems, causes, and corrective actions.

Fire Alarm & Error Signal Connection

Troubleshooting Common Issues

Unit Not Working Solutions

Solutions for common 'not working' issues and their checks.

Poor Cooling Solutions

Solutions for 'poor cooling' issues and their checks.

Maintenance Procedures

Overview

The AIRREX AHSC-140P 220/3 is a portable air conditioner with electric heat, designed for indoor use. This unit is certified by ETL Intertek, ensuring compliance with safety and quality standards.

Function Description:

The AIRREX AHSC-140P 220/3 provides versatile climate control with cooling, heating, fan, and dehumidification modes. It is designed to offer comfort and reliability in various environments. The unit features a digital controller for easy operation and monitoring of room temperature and settings. It also includes an "Off Timer" function, allowing users to schedule the unit to stop operation after a set period, ranging from 30 minutes to 24 hours. For safety, the unit incorporates error and warning indicators, as well as connections for fire alarm and external error signals.

Important Technical Specifications:

  • Model: AHSC-140P 220/3
  • Power Supply: 220 V~, 60 Hz, 3 Phase
  • Cooling Capacity: 145,000 Btu/h (42,500 W)
  • Heating Capacity: 100,000 Btu/h (29,300 W)
  • Cooling Power Consumption: 19.8 kW
  • Heating Power Consumption: 32 kW
  • Cooling Current Consumption: 61 A
  • Heating Current Consumption: 84.5 A
  • Dehumidification (Max/Nominal): 127 gal/day / 88 gal/day
  • Refrigerant: R-410A / 11 lb
  • Dimensions (W x D x H): 34 x 73 x 69 inches
  • Weight: 1,334 lb
  • Operating Conditions (Cooling): 65~113°F (18~45°C)
  • Operating Conditions (Heating): 1~81°F (-17~27°C)
  • Operating Conditions (Dehumidification): 59~113°F (15~45°C)
  • Power Cord: CAM LOCK

Usage Features:

The unit is equipped with a user-friendly digital control panel.

  • Power On/Off: A single button controls the unit's power.
  • Temperature Adjustment: Up and down arrow buttons allow precise setting of the desired temperature. The display shows both room/spot temperature and the set temperature.
  • Mode Selection: Dedicated buttons for Cooling, Fan, Dehumidifier, and Heat modes.
  • Off Timer: Users can set a stop time for the unit, with intervals of 30 minutes up to 10 hours, and then 1 hour up to 24 hours. The "Off Timer" lamp indicates when this mode is active.
  • Display Indicators:
    • 'Remote' LED: Indicates remote control operation.
    • 'Room' LED: When lit, the displayed temperature is the room temperature.
    • 'Comp.' LED: Indicates when the compressor is operating.
    • 'Error' LED: Signals an error condition.
  • Lock/Unlock Function: The control panel can be locked to prevent accidental changes. Pressing 'V' for 5 seconds when the unit is off activates this mode. A dot below the number on the screen indicates "LOCK" mode.
  • Temperature Unit Change: The display unit can be switched between Fahrenheit (°F) and Celsius (°C) by simultaneously pressing the 'V' and '^' buttons for 3 seconds when the unit is stopped.
  • Mobility: The unit is fitted with lockable casters for easy movement and secure positioning.
  • Ducting: Features flexible duct outlets for cold/hot air and return air, as well as a condenser inlet and outlet for hot air.
  • Condensate Management: Includes a condensate water outlet and a pump button to empty water from the pump.
  • Fire Alarm & Error Signal Connection: The unit can be integrated with external fire alarm systems and warning devices, providing an output signal (normal open dry contact) when an error occurs.

Maintenance Features:

Regular maintenance is crucial for optimal performance and longevity.

  • Filter Change: The unit features a paper pre-filter located inside. To change the filter:
    1. Detach the CABI LF (cabinet left) panel.
    2. Replace the filter.
    3. Reassemble in reverse order.
  • Cleaning: After cleaning, the unit should be operated in 'Fan' mode to completely dry the inside.
  • Outdoor Fan Grease Injection: Grease should be refilled every 1,000 hours.
    1. Remove two bolts.
    2. Inject grease into the port.
    3. Reassemble the two bolts.
  • Troubleshooting: The manual provides a comprehensive troubleshooting guide for common issues such as the unit not working, poor cooling, high pressure, low pressure, sensor errors (AF sensor, TH sensor), compressor issues, fan motor problems, heater overcurrent, water full, fire alarm signals, anti-freezing alarms, reverse phase, and overheat conditions. Each problem is linked to a specific error code displayed on the control panel and includes corrective actions. For example, if the COND filter is blocked or the exhaust duct is kinked, the unit may display an 'E1' error (High pressure), requiring cleaning of the filter and ensuring the duct is clear.

General Advice Before Use:

  • Ensure a safe, smooth, and level location for the unit.
  • Maintain at least 20 inches of space around the unit.
  • Lock the casters once the unit is in position.
  • Do not use the unit on an incline greater than 2°.
  • Always use a standard power cable. If the cable is damaged, it must be replaced by qualified personnel.
  • For maximum efficiency, use vertical exhaust into the ceiling in airtight areas and send exhaust outdoors through a window or door.
  • Ensure correct electricity supply.

Safety Instructions:

The manual emphasizes critical safety warnings and cautions, including:

  • Using a circuit breaker of appropriate capacity.
  • Disconnecting the unit before cleaning.
  • Avoiding damaged power cables or extension leads of unapproved types.
  • Not placing objects on top of the unit.
  • Preventing kinks or sharp bends in the power cable.
  • Turning off the control panel before the circuit breaker.
  • Using the unit on solid, flat surfaces.
  • Avoiding use in explosive environments, areas with flammable gas leakage, or where exposed to rain/water.
  • Not using solvents or spraying water on the unit for cleaning.
  • Ensuring the power cord and plug are undamaged and handled with dry hands.
  • Storing the unit in a dry, cool place when not in use.

The AIRREX AHSC-140P 220/3 is designed for robust performance and ease of use, with a strong focus on user safety and product reliability. The warranty covers manufacturing faults, provided the unit has not been misused or damaged by the customer.

Airrex HSC-60P Specifications

General IconGeneral
Cooling Capacity60, 000 BTU/h
Power Source220-240V, 50Hz
RefrigerantR410A
Noise Level65 dB
Operating Temperature Range18°C to 43°C