Indoor Units Outdoor Units
AWSI-HDD018-H11 AWSI-HED018-H11 AWAU-YDD018-H11
AWSI-HDD024-H11 AWSI-HED024-H11 AWAU-YDD024-H11
NOVEMBER – 2010
REFRIGERANT
R410A
HEAT PUMP
SM HDDHED 2-A.1 GB
Version: 1

Questions and Answers

  • J
    Jennifer LoganAug 18, 2025
    Why is my Airwell Air Conditioner showing over current protection?
    • S
      Sally SullivanAug 18, 2025
      The Airwell Air Conditioner might be showing an over current protection error because the supply voltage is unstable, or the supply voltage is too low while the load is too high.
  • G
    gutierrezcharlesAug 21, 2025
    Why does my Airwell AWAU-YDD024-H11 have indoor/outdoor coil over heating protection?
    • B
      Benjamin BrewerAug 21, 2025
      Your Airwell Air Conditioner might be experiencing indoor or outdoor coil over heating protection because the ambient temperature is too high or the heat exchange is poor, possibly due to a blockage or a bad radiating environment.
  • H
    Henry SmithAug 23, 2025
    Why does my Airwell Air Conditioner have HP switch protection?
    • J
      Johnathan KrauseAug 23, 2025
      HP switch protection in your Airwell Air Conditioner may be triggered by superabundant refrigerant, poor heat exchange (including blockage and bad radiating environment), or too high ambient temperature.
  • R
    Richard LongAug 26, 2025
    What causes compressor phase DC over current protection in Airwell AWAU-YDD024-H11?
    • M
      Mrs. Sara GonzalezAug 26, 2025
      Compressor phase DC over current protection in your Airwell Air Conditioner can be caused by several factors: 1. Abnormal power input voltage. 2. Compressor wiring mistake. 3. Liquid and gas valve are not open. 4. EEV damaged or not proper working. 5. Poor heat exchange. 6. Over charged system.
  • Z
    Zachary RobertsAug 27, 2025
    What causes indoor coil defrost protection in Airwell AWAU-YDD024-H11?
    • C
      Cheryl WolfeAug 28, 2025
      Indoor coil defrost protection in your Airwell Air Conditioner can be triggered by poor air-return in the indoor unit, abnormal fan speed, or a dirty evaporator.
  • D
    dperezAug 30, 2025
    Why is the Hz down on my Airwell Air Conditioner due to overload?
    • J
      jamesnorrisAug 30, 2025
      The Hz (Hertz) on your Airwell Air Conditioner might be decreasing due to an overload because the ambient temperature is too high, or the heat exchange is poor, potentially due to blockage or a bad radiating environment.
  • J
    Jay NelsonSep 1, 2025
    What causes Hz to drop due to over current in Airwell AWAU-YDD024-H11?
    • B
      burnettdanielSep 1, 2025
      A drop in Hz (Hertz) due to over current in your Airwell Air Conditioner can be caused by a power supply voltage that is too low, or higher system pressure and overload.
  • T
    Travis MasonSep 3, 2025
    Why is the Hz down on my Airwell AWAU-YDD024-H11 due to CTT over heating?
    • M
      Madison AdamsSep 3, 2025
      The Hz (Hertz) on your Airwell Air Conditioner might be decreasing due to CTT (Condenser Top Temperature) over heating because of overload, high temperature, insufficient refrigerant or an EEV problem.
  • M
    Matthew AndersonSep 6, 2025
    What causes DC over voltage in Airwell AWAU-YDD024-H11 Air Conditioner?
    • S
      Sean AlvarezSep 6, 2025
      DC over voltage in your Airwell Air Conditioner can be caused by an AC power supply higher than 265V or an outdoor PCB circuit malfunction.
  • A
    Amanda ChangSep 8, 2025
    What causes RAT failure in Airwell AWAU-YDD024-H11 Air Conditioner?
    • C
      Christopher RoseSep 8, 2025
      RAT (Room Air Temperature) failure in your Airwell Air Conditioner can be caused by a broken or damaged sensor, or a problem with the PCB temperature detection circuit.

Summary

Introduction to Airwell HDD;HED DCI Series

System Features and Unit Description

Overview of the HDD/HED series, main features, and indoor unit details.

Control and Outdoor Unit Details

Information on the control system, outdoor unit components, and tubing connections.

Tubing Connections and Documentation

Details on tubing connections and included documentation for the units.

Product Data Sheet

HDD018;HED018;YDD018 Specifications

Technical specifications for the HDD018/HED018 indoor and YDD018 outdoor units.

HDD024;HED024;YDD024 Specifications

Technical specifications for the HDD024/HED024 indoor and YDD024 outdoor units.

Rating Conditions

Operating Limits and Voltage

Defines the operational limits for cooling and heating based on temperature and voltage.

Outline Dimensions

Indoor Unit Dimensions and Mounting

Physical dimensions and mounting frame details for indoor units.

Outdoor Unit Dimensions

Physical dimensions and mounting details for outdoor units.

Performance Data & Pressure Curves

HDD018;HED018 Cooling and Heating Performance

Cooling and heating capacity, power input, and fan performance data.

HDD018;HED018 Performance Graphs

Graphs showing suction pressure, input current, and capacity correction factors.

HDD024;HED024 Cooling and Heating Performance

Cooling and heating capacity, power input, and fan performance data.

HDD024;HED024 Performance Graphs

Graphs showing suction pressure, input current, and capacity correction factors.

Sound Level Characteristics

Indoor Unit Sound Levels

Sound pressure level measurements and spectrum for indoor units.

Outdoor Unit Sound Levels

Sound pressure level measurements and spectrum for outdoor units.

Electrical Data

Single Phase Unit Specifications

Power supply, current, breaker rating, and wiring specifications for single phase units.

Wiring Diagrams

Indoor and Outdoor Unit Wiring Diagrams

Detailed wiring diagrams for indoor and outdoor units, including legends.

Refrigeration Diagrams

Refrigeration Diagrams for HDD;HED;YDD Models

Refrigeration circuit diagrams for specified indoor and outdoor unit model combinations.

Tubing Connections

Tube Bending and Torque Specifications

Guidelines for bending refrigerant tubing and torque values for fittings.

Control System

Electronic Control System Overview

Introduction to electronic control, abbreviations, and system operation concept.

Compressor and Fan Control Logic

Details on compressor frequency control, indoor and outdoor fan speed management.

System Operation Modes

Explanation of Cool, Heat, Dry, and Auto modes, including fan and compressor operation.

Special Functions (Sleep, I-Feel)

Description of Sleep function for temperature adjustment and I-Feel for remote sensing.

Protection Mechanisms Overview

Listing and brief explanation of various protection codes for the unit.

Unit Indicators and Test Mode

Information on unit indicators, display functions, and procedures for entering test mode.

Troubleshooting

Safety and Diagnostic Precautions

General safety guidelines and precautions before performing inspection or repair.

Error Code Interpretation

Guidance on how to interpret error codes displayed by the unit for diagnosis.

Refrigeration System and Main Part Checks

Procedures for checking the refrigeration system and main components.

Exploded Views and Spare Parts Lists

Indoor Unit Exploded Views and Parts

Exploded diagrams and parts lists for indoor units HDD018/024 and HED018/024.

Outdoor Unit Exploded Views and Parts

Exploded diagrams and parts lists for outdoor units YDD018 and YDD024.

Appendix A

Manuals Reference

Reference to separate Installation and Operation Manuals for HDD/HED018-024 units.

Airwell AWAU-YDD024-H11 Specifications

General IconGeneral
BrandAirwell
ModelAWAU-YDD024-H11
CategoryAir Conditioner
LanguageEnglish

Related product manuals