Service Manual
Flow Logic III

Questions and Answers

  • Z
    zparkerAug 20, 2025
    What to do if my Airwell Air Conditioner shows a cooling/heating lack of refrigerant alarm?
    • K
      Kristen LoveAug 20, 2025
      If your Airwell Air Conditioner is showing a cooling or heating alarm due to a lack of refrigerant, you should check the unit for refrigerant leakage and verify the readings from the high and low pressure sensors are accurate.
  • D
    Darius SkinnerAug 21, 2025
    How to fix EEPROM failure in Airwell Air Conditioner?
    • D
      Dr. Laura Keith DDSAug 22, 2025
      In case of EEPROM failure in your Airwell Air Conditioner, turn both BM1_1 and M1_2 to the "OFF" position, then re-energize the unit to see if the error clears.
  • R
    Rebecca ScottAug 25, 2025
    What to do if Airwell AWAU-YDV400-H13 Air Conditioner four-way valve reversing failure?
    • C
      Cassandra BurnsAug 25, 2025
      If your Airwell Air Conditioner's four-way valve is failing to reverse, have it replaced by after-sales service on site and ensure there is enough refrigerant.
  • E
    Elizabeth JacksonAug 26, 2025
    How to fix communication failure between indoor and outdoor unit of Airwell AWAU-YDV400-H13?
    • J
      Jeffery SmithAug 26, 2025
      If your Airwell Air Conditioner has communication issues between the indoor and outdoor units, have it replaced correctly by after- sales personnel on site.
  • J
    Jill BartonAug 27, 2025
    What to do if low pressure sensor disconnection failure in Airwell AWAU-YDV400-H13 Air Conditioner?
    • D
      Donna PerryAug 28, 2025
      If your Airwell Air Conditioner is showing a low pressure sensor disconnection failure, have it replaced correctly by after- sales personnel on site.
  • X
    xnguyenAug 30, 2025
    What to do if high pressure sensor disconnection failure in Airwell AWAU-YDV400-H13 Air Conditioner?
    • N
      Natalie LeeAug 30, 2025
      If your Airwell Air Conditioner is showing a high pressure sensor disconnection failure, have it replaced correctly by after- sales personnel on site.
  • R
    rickybaldwinSep 1, 2025
    What to do if high pressure switch disconnection failure in Airwell Air Conditioner?
    • R
      Ronald BergerSep 1, 2025
      If your Airwell Air Conditioner is showing a high pressure switch disconnection failure, have it replaced correctly by after- sales personnel on site.
  • B
    Brian GreenSep 3, 2025
    What to do if the unit compression ratio is too low in Airwell Air Conditioner?
    • M
      Michelle MorrisSep 3, 2025
      If your Airwell Air Conditioner indicates the unit compression ratio is too low, have it replaced correctly by after- sales personnel on site and ensure there is enough refrigerant.
  • R
    Ryan Green MDSep 5, 2025
    How to fix communications between outdoor units failure in Airwell AWAU-YDV400-H13?
    • L
      lowejohnSep 5, 2025
      If your Airwell Air Conditioner is experiencing communications failure between outdoor units, have it replaced correctly by after- sales personnel on site.
  • D
    Diana FisherSep 7, 2025
    What to do if fan motor 1 or 2 overcurrent in Airwell AWAU-YDV400-H13?
    • S
      Sarah IrwinSep 7, 2025
      If your Airwell Air Conditioner's fan motor 1 (left fan) or fan motor 2 (right fan) is showing an overcurrent, have it replaced correctly by after-sales personnel on site.

Summary

Products lineup

Specification

Piping diagram

Wiring diagram

Capacity calculation due to capacity modification coefficient

Installation

Safety

Emphasizes critical safety precautions to prevent injury and damage during installation.

Construction of refrigerant pipe

Specifies pipe materials, dimensions, lengths, and connection methods for refrigerant piping.

Branch pipe dimensions

Gather pipe dimension

Trial operation

Outdoor PCB dip switch setting

Outdoor system control function

Start Control

Describes compressor start conditions, protection, and restart logic for safe operation.

Pressure protection control

Outlines protection mechanisms against high and low pressure faults.

Overheating protection control

Manages compressor overheating to ensure safe operation.

Current protection control

Protects against excessive compressor current by adjusting operating frequency.

Failure code

Troubleshooting

Airwell AWAU-YDV400-H13 Specifications

General IconGeneral
Seasonal Energy Efficiency Ratio (SEER)6.1
RefrigerantR410A
Cooling Capacity4.0 kW
Heating Capacity4.2 kW
Energy Efficiency Ratio (EER)3.2
Power Supply220-240V/50Hz/1Ph
Noise Level (Outdoor Unit)52 dB(A)
TypeSplit System Air Conditioner