Airwell BS 12 DCI - User Manual

Airwell BS 12 DCI
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
BS DCI Series
Indoor Units Outdoor Units
BS 12 DCI GC 12 DCI
OCTOBER – 2008
REFRIGERANT
R410A
HEAT PUMP
SM BS DCI 1-A.1 GB
CONTENTS

Questions and Answers

  • K
    Kenneth RogersAug 7, 2025
    What to do if the compressor of my Airwell BS 12 DCI Heat Pump does not start?
    • L
      Lisa BrownAug 7, 2025
      If the compressor of your Airwell Heat Pump doesn't start, it may be due to an electronics control problem or protection issue. You should perform diagnostics as described in section 11.3 of the manual and follow the recommended actions.
  • B
    boydhollyAug 11, 2025
    Why is my Airwell BS 12 DCI Heat Pump not responding to the remote control?
    • M
      Mr. Paul ParrishAug 11, 2025
      If your Airwell Heat Pump unit isn't responding to the remote control, the remote control message may not be reaching the indoor unit. First, check the remote control batteries. If the batteries are fine, inspect the display and display wiring. If those are OK, replace the display PCB. If the unit still doesn't respond, replace the controller.
  • J
    Jeffrey MorenoAug 16, 2025
    What to do if the compressor of my Airwell Heat Pump stops during operation?
    • K
      Kimberly OsborneAug 16, 2025
      If the compressor in your Airwell Heat Pump stops during operation but the green LED remains on, it could be due to an electronic control or power supply problem. You should perform diagnostics as described in section 11.3 of the manual and follow the recommended actions.
  • K
    kgardnerAug 20, 2025
    Why is the indoor fan of my Airwell Heat Pump not starting?
    • G
      Glen StevensAug 20, 2025
      If the indoor fan of your Airwell Heat Pump doesn't start, but the louvers are open and the green LED is lit, there could be a few reasons: * If the unit is in heat mode, the coil might not be warm yet. Try changing to cool mode to test. * There might be a problem with the PCB or capacitor. Switch to high speed and check if the power supply to the motor is higher than 130VAC (for triack controlled motor) or higher than 220VAC for fixed speed motors. If it is, replace the capacitor. If not, replace the controller.
  • J
    Janet KnoxAug 25, 2025
    What to do if Airwell Heat Pump responds to remote but the Green LED doesn't light up?
    • J
      joel20Aug 25, 2025
      If your Airwell Heat Pump responds to the remote control message but the Operate indicator (Green LED) doesn't light up, there may be a problem with the display PCB. Replace the display PCB. If the issue persists, replace the controller.
  • G
    George LunaAug 28, 2025
    Why is the indoor fan of my Airwell BS 12 DCI Heat Pump working when the unit is off?
    • C
      Casey MillsAug 29, 2025
      If the indoor fan of your Airwell Heat Pump is working when the unit is OFF, and the fan speed can't be changed with the remote, it indicates a PCB problem. Replace the controller.
  • K
    Kathleen FosterSep 2, 2025
    How to fix a power supply indicator (Red LED) that does not light up on my Airwell BS 12 DCI?
    • K
      Karla MontoyaSep 2, 2025
      If the power supply indicator (Red LED) on your Airwell Heat Pump doesn't light up, it indicates there's no power supply. Check the power supply. If the power supply is OK, check the display and display wiring. If those are OK, replace the controller.

Airwell BS 12 DCI Specifications