SX DCI Series
Indoor Units Outdoor Units
SX 9 DCI GC 9 DCI
SX 12 DCI GC 12 DCI
SX 18 DCI GC 18 DCI
SX 24 DCI GC 24 DCI
SX 30 DCI GC 30 DCI
AUGUST – 2008
REFRIGERANT
R410A
HEAT PUMP
SM SX DCI 1-A.3 GB
CONTENT

Questions and Answers

  • M
    Megan NixonAug 4, 2025
    What to do if the compressor of my Airwell Heat Pump does not start?
    • N
      Natasha MitchellAug 4, 2025
      If the compressor of your Airwell Heat Pump doesn't start, it may be due to an electronics control problem or protection issue. You should perform diagnostics as described in section 11.3 of the manual and follow the recommended actions.
  • S
    Shannon Powers PhDAug 8, 2025
    Why is my Airwell GC 12 DCI not responding to the remote control?
    • M
      martin21Aug 8, 2025
      If your Airwell Heat Pump unit isn't responding to the remote control, the remote control message may not be reaching the indoor unit. First, check the remote control batteries. If the batteries are fine, inspect the display and display wiring. If those are OK, replace the display PCB. If the unit still doesn't respond, replace the controller.
  • D
    David SmithAug 12, 2025
    What to do if the compressor of my Airwell GC 12 DCI stops during operation?
    • B
      bensonrobertAug 12, 2025
      If the compressor in your Airwell Heat Pump stops during operation but the green LED remains on, it could be due to an electronic control or power supply problem. You should perform diagnostics as described in section 11.3 of the manual and follow the recommended actions.
  • R
    Robert HerreraAug 17, 2025
    Why is the indoor fan of my Airwell GC 12 DCI Heat Pump not starting?
    • M
      Michelle JohnsonAug 17, 2025
      If the indoor fan of your Airwell Heat Pump doesn't start, but the louvers are open and the green LED is lit, there could be a few reasons: * If the unit is in heat mode, the coil might not be warm yet. Try changing to cool mode to test. * There might be a problem with the PCB or capacitor. Switch to high speed and check if the power supply to the motor is higher than 130VAC (for triack controlled motor) or higher than 220VAC for fixed speed motors. If it is, replace the capacitor. If not, replace the controller.
  • K
    Kayla KelleyAug 21, 2025
    What to do if Airwell GC 12 DCI responds to remote but the Green LED doesn't light up?
    • J
      Julie ThompsonAug 21, 2025
      If your Airwell Heat Pump responds to the remote control message but the Operate indicator (Green LED) doesn't light up, there may be a problem with the display PCB. Replace the display PCB. If the issue persists, replace the controller.
  • C
    Christopher GreenAug 25, 2025
    Why is the indoor fan of my Airwell GC 12 DCI Heat Pump working when the unit is off?
    • J
      John HoffmanAug 26, 2025
      If the indoor fan of your Airwell Heat Pump is working when the unit is OFF, and the fan speed can't be changed with the remote, it indicates a PCB problem. Replace the controller.
  • A
    Andrew WilliamsAug 29, 2025
    How to fix a power supply indicator (Red LED) that does not light up on my Airwell GC 12 DCI Heat Pump?
    • P
      patelwalterAug 29, 2025
      If the power supply indicator (Red LED) on your Airwell Heat Pump doesn't light up, it indicates there's no power supply. Check the power supply. If the power supply is OK, check the display and display wiring. If those are OK, replace the controller.

Summary

Introduction to the SX DCI Series

General Information

Overview of the SX split ceiling mounted range, including heat pump models.

Main Features of the SX Series

Highlights the advanced technological innovations and benefits of the SX series.

Indoor Unit Description

Details the features and components of the floor/ceiling mounted indoor unit.

Filtration System

Describes the filtration types and accessibility for the SX series.

Control System Overview

Explains the microprocessor indoor controller and infrared remote control.

Outdoor Unit Description

Details the features, installation, and components of the outdoor units.

Tubing Connections

Information on flare type interconnecting tubing installation.

Accessories and Documentation

Covers remote control accessories and provided documentation.

Matching Table and Refrigerant

Details the matching table for indoor/outdoor units and R410A refrigerant.

Product Data Sheets

SX 9 DCI R410 A Specifications

Provides detailed technical specifications for the SX 9 DCI model.

SX 12 DCI R410 A Specifications

Provides detailed technical specifications for the SX 12 DCI model.

SX 18 DCI R410 A Specifications

Provides detailed technical specifications for the SX 18 DCI model.

SX 24 DCI R410 A Specifications

Provides detailed technical specifications for the SX 24 DCI model.

SX 30 DCI R410 A Specifications

Provides detailed technical specifications for the SX 30 DCI model.

Rating Conditions and Operating Limits

Standard Rating Conditions

Defines standard conditions for cooling and heating operations.

Operating Limits for R410 A

Specifies the operating limits for cooling, heating, and voltage.

Outline Dimensions

Indoor Unit Dimensions (SX 9, 12 DCI)

Provides dimensional drawings for SX 9 and 12 DCI indoor units.

Indoor Unit Dimensions (SX 18, 24, 30 DCI)

Provides dimensional drawings for SX 18, 24, and 30 DCI indoor units.

Outdoor Unit Dimensions (GC 9, 12, 18 DCI)

Provides dimensional drawings for GC 9, 12, and 18 DCI outdoor units.

Outdoor Unit Dimensions (GC 24, 30 DCI)

Provides dimensional drawings for GC 24 and 30 DCI outdoor units.

Performance Data and Pressure Curves

SX 9 DCI Performance Data

Cooling and heating capacity data, power input, and correction factors.

SX 12 DCI Performance Data

Cooling and heating capacity data, power input, and correction factors.

SX 18 DCI Performance Data

Cooling and heating capacity data, power input, and correction factors.

SX 24 DCI Performance Data

Cooling and heating capacity data, power input, and correction factors.

SX 30 DCI Performance Data

Cooling and heating capacity data, power input, and correction factors.

Tubing Length Capacity Correction Factors

Correction factors for cooling and heating based on tubing length.

Sound Level Characteristics

Indoor Unit Sound Pressure Levels

Sound pressure level spectrums for SX 9, 12, 18, 24, 30 indoor units.

Outdoor Unit Sound Pressure Levels

Sound pressure level spectrums for GC 9, 12, 18, 24, 30 outdoor units.

Electrical Data

Single Phase Unit Electrical Specifications

Details power supply, current ratings, and wiring specifications.

Wiring Diagrams

Wiring Diagram for SX 9, 12, 18 DCI; GC 9, 12, 18 DCI

Circuit diagram for indoor and outdoor units of specific models.

Wiring Diagram for Indoor Unit SX 24, 30 DCI

Circuit diagram for SX 24 and 30 DCI indoor units.

Wiring Diagram for Outdoor Unit GC 24, 30 DCI

Circuit diagram for GC 24 and 30 DCI outdoor units.

Refrigeration Diagrams

Refrigeration Flow for SX 9-30 DCI

Illustrates refrigerant flow for cooling and heating modes.

Tubing Connections

Refrigerant Tubing Installation Guide

Details tubing connections, torque specifications, and oil trap requirements.

Troubleshooting Guide

General DCI Split System Faults

Common symptoms, probable causes, and corrective actions for system failures.

Refrigeration System Checks

Procedures for checking system pressures and thermodynamic measures.

Indoor;Outdoor Unit Diagnostics

Guidance on entering and interpreting unit diagnostic modes.

MegaTool Usage for System Monitoring

Instructions for using MegaTool to monitor system states.

Main Part Checks

Simple procedures for checking mains voltage, power input, and fan motor.

Safety Precautions and Advises

Important notices regarding high voltage, charged capacitors, and disassembly.

Control System Operation

General Functions and Operating Rules

Overview of DCI software, parametric controls, and system operation concept.

Compressor Frequency Control

Details on NLOAD setting and target frequency calculations.

Indoor Fan Control

Explanation of indoor fan speeds, turbo speed, and auto fan operation.

Outdoor Fan Control

Fan speed control routines based on operating conditions.

EEV (Electronic Expansion Valve) Control

Details on EEV opening control for different unit models.

Protections and Fault Codes

Description of protection mechanisms like defrost, overheating, and current limits.

Unit Controls and Indicators

Explanation of indoor and outdoor unit controls and status indicators.

Test Mode Operation

Procedures for entering and operating the unit in test mode.

SW Parameters

Lists model-dependent software parameters for various units.

Exploded Views and Spare Parts Lists

Indoor Unit Exploded View (SX 9, 12 DCI)

Exploded diagram of the SX 9 and 12 DCI indoor unit.

Indoor Unit Spare Parts (SX 9, 12 DCI)

List of spare parts for SX 9 and 12 DCI indoor units with part numbers.

Indoor Unit Exploded View (SX 18, 24, 30 DCI)

Exploded diagram of the SX 18, 24, and 30 DCI indoor unit.

Indoor Unit Spare Parts (SX 18 DCI)

List of spare parts for SX 18 DCI indoor units with part numbers.

Indoor Unit Spare Parts (SX 24, 30 DCI)

List of spare parts for SX 24 and 30 DCI indoor units with part numbers.

Outdoor Unit Exploded View (GC 9, 12 DCI)

Exploded diagram of the GC 9 and 12 DCI outdoor unit.

Outdoor Unit Spare Parts (GC 9, 12 DCI)

List of spare parts for GC 9 and 12 DCI outdoor units with part numbers.

Outdoor Unit Spare Parts (GC 18 DCI)

List of spare parts for GC 18 DCI outdoor units with part numbers.

Outdoor Unit Spare Parts (GC 24, 30 DCI)

List of spare parts for GC 24 and 30 DCI outdoor units with part numbers.

Appendix A

Installation and Operation Manuals

References to separate operation and installation manuals for SX series.

Airwell GC 12 DCI Specifications

General IconGeneral
BrandAirwell
ModelGC 12 DCI
CategoryHeat Pump
LanguageEnglish

Related product manuals