EasyManua.ls Logo

Airwell DAF009 - 8.4 Outdoor Units

Airwell DAF009
171 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICAL DATA
8-2 SM YIF 2-A.1 GB
8.4 Outdoor units
Circuit Breaker
Power Supply
Wiring No. X
Cross Section
Interconnecting Cable
Model No. X Cross Section
Model
Power Supply
(V,Ph,Hz)
(A) (mm
2
) (mm
2
)
YIF009 220-240,1,50 10 3 X2.5 2 X0.75
YIF012 220-240,1,50 13 3 X2.5 2 X0.75
YIF018 220-240,1,50 20 3 X2.5 2 X0.75
YIF024 220-240,1,50 25 3 X2.5 2 X0.75
YIF030 220-240,1,50 30 3 X6.0 2 X0.75
YIF036 220-240,1,50 40 3 X6.0 2 X0.75
YIF036T 380-415,3,50 16 5 X4.0 2 X0.75
YIF042T 380-415,3,50 20 5 X4.0 2 X0.75
YIF060T 380-415,3,50 20 5 X4.0 2 X0.75
NOTE
Power wiring cord should comply with local laws and electrical regulations requirements.