Airwell SX 9 DC INV User Manual

Airwell SX 9 DC INV
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Multi Split DUO DCI
REFRIGERANT
R410A
HEAT PUMP
TM DUODCI-A-1-GB JUNE 2005
Indoor Units Outdoor Units
FLO 9 DC INV
DUO 50 DCI
FLO 12 DC INV
SX 9 DC INV
SX 12 DC INV
BS 12 DC INV
K
9 DC INV
K
12 DC INV
Technical Manual
Question and Answer IconNeed help?

Do you have a question about the Airwell SX 9 DC INV and is the answer not in the manual?

Airwell SX 9 DC INV Specifications

General IconGeneral
RefrigerantR32
Power Supply220-240V, 50Hz
TechnologyInverter
TypeSplit System
Weight8 kg (Indoor)

Summary

Product Data Sheet

Outdoor Unit DUO 50 DCI Specifications

Technical specifications for the DUO50 DCI outdoor unit.

Indoor Units Data

Performance and specification data for various indoor units.

FLO 9 DCI Specifications

Detailed specs for the FLO 9 DCI indoor unit.

FLO 12 DCI Specifications

Detailed specs for the FLO 12 DCI indoor unit.

K 9 DCI Specifications

Detailed specs for the K 9 DCI indoor unit.

K 12 DCI Specifications

Detailed specs for the K 12 DCI indoor unit.

SX 9 DCI Specifications

Detailed specs for the SX 9 DCI indoor unit.

SX 12 DCI Specifications

Detailed specs for the SX 12 DCI indoor unit.

BS 12 DCI Specifications

Detailed specs for the BS 12 DCI indoor unit.

Rating Conditions

Operating Limits

Operating temperature and voltage limits for the system.

Outline Dimensions

Performance Data

FLO 9 DCI

Cooling and heating performance data for FLO 9 DCI.

FLO 12 DCI

Cooling and heating performance data for FLO 12 DCI.

K 9 DCI

Cooling and heating performance data for K 9 DCI.

Cooling Capacity (kW) - Run Mode(Unit A or B)

Cooling capacity table for K 9 DCI.

Heating Capacity (kW) - Run Mode(Unit A or B)

Heating capacity table for K 9 DCI.

K 12 DCI

Cooling and heating performance data for K 12 DCI.

SX 9 DCI

Cooling and heating performance data for SX 9 DCI.

SX 12 DCI

Cooling and heating performance data for SX 12 DCI.

BS12 DCI

Cooling and heating performance data for BS12 DCI.

Cooling Capacity (kW) - Run Mode (Unit A or B)

Cooling capacity table for BS12 DCI.

Heating Capacity (kW) - Run Mode (Unit A or B)

Heating capacity table for BS12 DCI.

Wiring Diagrams

DUO 50 DCI Wiring Diagram

Electrical wiring diagram for the DUO 50 DCI.

Refrigeration Diagrams

DUO 50 DCI => Cooling Mode

Refrigeration diagram for DUO 50 DCI cooling mode.

DUO 50 DCI => Heating Mode

Refrigeration diagram for DUO 50 DCI heating mode.

Control System

Protections

Overview of the 5 protection codes.

Indoor Coil Defrost Protection

Protection against indoor coil icing during defrost.

Indoor Coil over Heating Protection

Protection against indoor coil overheating.

Compressor over Heating Protection

Protection against compressor overheating based on temperature.

Compressor over Current Protection

Protection against compressor over current.

Heat Sink Over Heating Protection (NA for DCI 9 and 12)

Protection against heat sink overheating.

Outdoor Coil Deicing Protection

Protection against outdoor coil icing during deicing.

Deicing Starting Conditions

Conditions that trigger deicing operation.

Deicing Protection Procedure

Procedure for outdoor coil deicing.

Condensate Water Over Flow Protection

Protection against condensate water overflow.

Levels Logic (used in floor/ceiling models)

Logic for condensate overflow detection in floor/ceiling models.

1 Level Logic (used in all models except for floor/ceiling models)

Logic for condensate overflow detection in other models.

Jumper Settings

Various jumper settings for unit control.

Troubleshooting

Related product manuals