EasyManua.ls Logo

Airwell GC 24 - Page 58

Airwell GC 24
105 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12-8
CONTROL SYSTEM
SM FLODCI 2-A.4 GB
12.7.2.2 Indoor Coil Overheating Protection For FLO 24 / 30
ICT
ICT Trend
<-2 -2 -1,0,1 2 >2
ICT >62 SC SC SC SC SC
60 ≤ ICT < 62 D1 D1 D2 D2 D2
58≤ ICT <60 SR SR D1 D2 D2
56≤ ICT < 58 SR SR SR D1 D2
54≤ ICT < 56 Norm Norm SR SR D1
52≤ ICT 54 Norm Norm Norm SR SR
ICT <52 Norm
12.7.3 Compressor Overheating Protection
12.7.3.1 Compressor Overheating Protection for GC 18 / 21 / 24 Z
Compressor temperature can be in one of 5 control zones (4 in protection, and 1 normal),according
to the following chart.
Normal
P1
P2
P3
Sto
p
-Com
p
resso
r
94
98
102
105
CTT
Control Status
Compressor Temperature
Increases
Else
P1 Normal Stop Rise
P2 HzDown 1 Stop Rise
P3 HzDown 2 HzDown 1
Stop Compressor Stop Compressor
CONTENTS