TROUBLE SHOOTING
HKD DCI 47 Version - 2
11.1 8.1 Indoor Unit Error Display
Operation
lamp
Timer lamp
Display
LED STATUS
1 time
X
E0
Indoor unit EEPROM parameter error
2 times
X
E1
Indoor / outdoor units communication error
4 times
X
E3
Indoor fan speed has been out of control
5 times
X
E4
Indoor room temperature sensor T1 open circuit or short
circuit
6 times
X
E5
Evaporator coil temperature sensor T2 open circuit or
short circuit
7 times
X
EC
Refrigerant leakage detection
1 times
O
F0
Overload current protection
2 times
O
F1
Outdoor ambient temperature sensor T4 open circuit or
short circuit
3 times
O
F2
Condenser coil temperature sensor T3 open circuit or
short circuit
4 times
O
F3
Compressor discharge temperature sensor T5 open
circuit or short circuit
5 times
O
F4
Outdoor unit EEPROM parameter error
6 times
O
F5
Outdoor fan speed has been out of control
1 times
P0
IPM malfunction or IGBT over-strong current protection
2 times
P1
Over voltage or over low voltage protection
3 times
P2
High temperature protection of compressor top
diagnosis and solution
5 times
P4
Inverter compressor drive error
Olight Xoff ☆(flash

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Airwell HKD DCI Series and is the answer not in the manual?

Airwell HKD DCI Series Specifications

General IconGeneral
BrandAirwell
ModelHKD DCI Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals