PRODUCT SPECIFICATION
HKD DCI 7 Version - 2
3. Product Specification
3.1 AWSI-HKD009-N11 / AWAU-YKD009-H11
MODEL INDOOR UNIT
AWSI-HKD009-N11
Model Outdoor Unit
AWAU-YKD009-H11
Installation Method of Pipe
Flared
Characteristics
Units
Cooling
Heating
Average
Warm
Cold
Capacity
(1)
kW
2.65(1.2-3.3)
2.8(0.85-3.7)
Pdesign
kW
2.65
2.4
2.8
3
SEER /SCOP
(2)
W/W
6.9
4
5.1
3.3
Energy efficiency class
A++
A+
A+++
B
Annual energy consumption
kWh
135
840
769
1910
Tbiv
o
C
N/A
-7
2
-15
Tol
o
C
N/A
-15
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Circuit breaker rating
A
10
INDOOR
Fan type & quantity
Cross flow fan x1
Fan speeds
H/M/L/VL
RPM
1150 / 1000 / 800
Air flow
(3)
H/M/L/VL
m3/hr
430/380/320/230
External static pressure
Min-Max
Pa
0
Sound power level
(4)
H/M/L
dB(A)
54
Sound pressure level
(5)
H/M/L/VL
dB(A)
38/35/31/22
Moisture removal
l/hr
1
Condensate drain tube I.D
mm
16
Dimensions
WxHxD
mm
715x250x188
Weight
kg
6.5
Package dimensions
LxWxH
mm
775x260x324
Packaged weight
kg
8.2
Stacking height
units
8
OUTDOOR
Refrigerant control
EEV
Compressor type, model
Rotary DC Inverter
Fan type & quantity
Axial x 1
Fan speeds
H/L
RPM
810/710/520
Air flow
H/L
m3/hr
1900
Sound power level
(4)
H/L
dB(A)
60
Sound pressure level
(5)
H/L
dB(A)
50
Dimensions
WxHxD
mm
770x300x555
Weight
kg
26.6
Package dimensions
LxWxH
mm
900x345x585
Packaged weight
kg
29
Stacking height
Units
4
Refrigerant type
R410A
Refrigerant charge (standard connecting tubing length)
kg(5m)
0.8
Additional charge per 1 meter
gr / 1m
15
Connections between units
Liquid line
In.(mm)
1/4’’
Suction line
In.(mm)
3/8’’
Max.tubing length
m.
25
Max.height difference
m.
10
Operation control type
Remote control
Heating elements
kW
NA
Others
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units).
(2) SEER / SCOP calculation accordance with EN14825.