Questions and Answers

  • B
    Benjamin BaxterSep 9, 2025
    Why does my Airwell Air Conditioner fan run when off, and remote control doesn't work?
    • S
      shallSep 9, 2025
      If the indoor fan of your Airwell Air Conditioner runs when the unit is off, and the fan speed can't be changed with the remote, there's likely a controller problem. Replace the controller.
  • M
    Michael HerringAug 23, 2025
    Why is my Airwell YAZ318 Air Conditioner compressor running but not cooling?
    • S
      smartinezAug 23, 2025
      If the compressor of your Airwell Air Conditioner is running but some units aren't generating capacity, several issues could be the cause. It could be an EEV problem, refrigerant leakage, or a blocked indoor or outdoor coil. Check the EEV, refrigeration system, and clean filters or remove any blockages from the coils.
  • K
    Kelly JohnsonAug 25, 2025
    Why is my Airwell YAZ318 Air Conditioner running but not cooling or heating?
    • D
      diamondtaylorAug 25, 2025
      If all components of your Airwell Air Conditioner are running correctly, but you're not getting any cooling or heating, the issue is likely a refrigerant leak. Check the refrigeration system for leaks.
  • E
    Emily WilliamsAug 27, 2025
    Why is my Airwell YAZ318 Air Conditioner leaking water inside?
    • P
      Paige RamirezAug 27, 2025
      If you notice water leaking from your Airwell Air Conditioner's indoor unit, it's likely that the drainage tube is blocked. Inspect the drainage tube and clear any blockage to resolve the leakage.
  • G
    Gregory HarveyAug 27, 2025
    What causes my Airwell Air Conditioner compressor to overheat and not cool?
    • U
      uscottAug 27, 2025
      If your Airwell Air Conditioner's compressor is overheating and the unit isn't generating capacity, it could be due to an EEV problem, refrigerant leakage, or a blocked indoor or outdoor coil. You should check the EEV, inspect the refrigeration system, and clean the filters or remove any blockages.
  • K
    Karen KelleyAug 29, 2025
    What to do if my Airwell Air Conditioner indoor fan won't start?
    • D
      davismeganAug 29, 2025
      If the indoor fan of your Airwell Air Conditioner isn't starting, but the louvers are open and the green LED is on, it could be due to several reasons. If the unit is in heat mode, the coil might not be warm yet, so try changing to cool mode. The outdoor unit might be in the opposite mode, so try changing the operation mode. Also, there could be a problem with the controller or capacitor. Try changing to high speed and check that the power supply to the motor is higher than 130VAC (for triack controlled motor) or higher than 220VAC for fixed speed motors, if OK replace capacitor, if not OK replace controller.
  • H
    holly76Sep 18, 2025
    What if my Airwell Air Conditioner responds to the remote but the green light is off?
    • J
      Julie BentleySep 18, 2025
      If your Airwell Air Conditioner's indoor unit responds to the remote control but the green LED doesn't light up, there's likely a problem with the display PCB. Replace the display PCB. If the issue persists, replace the controller.
  • E
    Eric WilliamsSep 22, 2025
    How to prevent my Airwell Air Conditioner outdoor unit from freezing?
    • D
      dyerdonaldSep 22, 2025
      To solve freezing of the outdoor unit in heat mode and ice blockage of the outdoor unit base of your Airwell Air Conditioner, connect a base heater.
  • J
    jwelchSep 7, 2025
    What does no OFAN feedback mean on my Airwell YAZ318?
    • J
      jbookerSep 8, 2025
      If there is no OFAN feedback in your Airwell Air Conditioner, it means that no encoder signal can be detected from the OFAN. Check the DC-FAN hall sensor connection/plug for damage. Check DC-FAN for any blockage. Measure between U-V, U-W for resistance using multimeter. Resistance value should be below 1 OHM. If multimeter display high resistance, replace DC-FAN motor, otherewise replace controller.
  • W
    williamsrickySep 4, 2025
    Why is my Airwell Air Conditioner stuck in the wrong mode?
    • K
      katiedukeSep 5, 2025
      If your Airwell Air Conditioner is working in the wrong mode (cooling instead of heating, or vice versa), it could be due to electronics or RV problems. Check the RV.