IV.
ELECTRICAL
ADJUSTMENT
[PRECAUTIONS
BEFORE
ADJUSTMENT]
1.
Before
adjustment,
clean
and
de-magnetize
heads
and
tape
guides.
ABOUT
THE
TEST
MODE
Be
sure
to
engage
the
test
mode
before
proceeding
with
electrical
adjustment
1.
To
engage
the
test
mode,short
the
TEST
AND
TEST
GND
2.
The
“CD
EDIT”
indicator
will
appear
on
the
front
panel
3.
To
disengage
the
test
mode
turn
the
power
off
STEP
|
ADJUSTMENT
ITEM
1.
TEST
TAPE/INPUT
SIGNAL
2.
MODE
3.
TEST
POINT/ADJUSTMENT
PART
4.
(©)
REMAKERS,
(*)
RESULT
Adjustment
Part
2.
|
TAPE
|
NORMAL
TAPE
SPEED
1.
3,150
Hz
test
tape
(AT-751263)
2.
PLAY
3.
AUX
/
VCR
OUT
/VR3
4.
e
Connect
a
frequency
counter
to
AUX
/
VCR
OUT.
*
3,150
+10
Hz
|
1
|
TAPE
|
(X2)
TAPE
SPEED
1.
3,150
Hz
test
tape
(AT-751263)
2.
PLAY
(Push
x
2
DUBBING
START
button)
3.
AUX
/
VCR
OUT
/
VR
14
4.
e
Connect
a
frequency
counter
to
AUX
/
VCR
OUT.
*
6,300
+20
Hz
TEST
MODE
a
TEST
TEST
GND
PRE
AMP
PCB
(View
from
parts
side)
-
|
TAPE
Il
NORMAL
TAPE
SPEED
1.
3,150
Hz
test
tape
(AT-751263)
2.
PLAY
3.
AUX
/
VCR
OUT
/
VR
4
4.
e
Connect
a
frequency
counter
to
AUX
/
VCR
OUT.
*
5
Hz
to
10
Hz
lower
than
the
result
in
STEP
2
[TAPE
1
NORMAL
TAPE
SPEED}
-
|
TAPE
II
(X2)
TAPE
SPEED
1.
3,150
Hz
test
tape
(AT-751263)
2.
PLAY
(Push
X2
DUBBING
START
button)
3.
AUX
/
VCR
OUT
/
VR
2
4.
©
Connect
a
frequency
counter
to
AUX
/
VCR
OUT.
**
5
Hz
to
10
Hz
lower
than
the
result
in
STEP
1
[TAPE
1
(X2)
TAPE
SPEED]