Step
Adjustment Test Tape
Mode
Adjustment
Item
Supply Signal
Parts
OP
Amp
VR7
1
Off.Set
i
STOP
Pre Amp
PCB
Voltage
2
PB
Level
333
Hz
Test Tape
PB
i
VR5
(TF-IOlCL) Pre Amp
PCB
!
10 kHz Test Tape VR6
3
PB
EQ
(TF-106CH)
PB
I
Pre Amp
PCB
Normal
Normal Blank Tape
Position
VRll
4
Frequency
1 kHz,
10
kHz
REC/PB
Pre Amp
PCB
Response
-25.5
dBm
CrO
2
I
CrO
2
Blank Tape
5
i
Position
1 kHz, 10 kHz
REC/PB
VRIO
Frequency
I
-25.5
dBm
Pre Amp
PCB
Response
Metal
Metal Blank Tape
Position VR9
6
Frequency
I
I kHz, 10 kHz REC/PB
Pre Amp
PCB
Response
-25.5
dBm
7
REC Level
I
Normal Blank Tape
REC/PB
VR8
1 kHz,
-5.5
dBm Pre Amp
PCB
8
MPX
Filter
I
19
kHz
REC
FL4
from oscillator Pre Amp
PCB
9
Bias Filter
No
Signal Input REC
FL3
Pre Amp
PCB
I 10
VU Meter
1 kHz,
-5
.5
dBm
REC
VR4
Sensitivity from oscillator Pre Amp
PCB
NOTES:
1.
Output volume should be at maximum.
2. Dolby NR Switch
to
OFF Position.
3. Except
for Step 8 set Dolby Filter Switch
to
OFF Position.
4.
Use
the following cassette measuring tapes:
Normal Tape Maxell
UD
C-60
CrO
2
Tape TDK
SA
C-60
Metal Tape TDK
MA-C
C-60
For your reference:
Confirmation
of
Dolby level
I)
Set
to
REC/PAUSE.
GX-F51
I
Result Remarks
TPl
0
0.1
VDC
-5.5
± 0.5 dBm
(410 mV)
-22.5
± 1.5 dBm
1 kHz
to
10 kHz
flat response
1 kHz
to
IO
kHz
flat response
I kHz to
IO
kHz
flat response
I
-5.5
± 0.3 dBm
I
(410 mV)
Minimum
Output
MPX Filter
ON
Minimum
Output
Set REC Volume
to
maximum
0
dB
(VU)
indication
2)
Input
a signal
of
400
Hz
and adjust the input level so that the level
of
pin
580
mV when Dolby
NR
is
OFF.
of
Dolby
LC
(HA-12038) will be
3)
Check
that
the
level
of
TP-2
is
580 mV.
3-7