EasyManua.ls Logo

Akai MX-550

Akai MX-550
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IV.
ELECTRICAL
ADJUSTMENT
Before
making
adjustments
1
-
5,
load
a
test
disc
as
follows.
After
first
setting
the
unit
to
the
test
mode
1,
press
the
»/#
button
to
open
the
disc
tray
and
place
a
SONY
TYPE
3
test
disc
on
the
DISC
1
holder.
Press
the
»/4
button
again
to
close
the
tray.
Adjustments
can
now
be
made.
1.
TEST
DISC
Test
point
ADJUSTMENT
2.
MODE
or
TEST
mode
3.
TEST
POINT
and
ADJUSTMENT
parts.
4.
REMARK
(¢),
RESULT
(-)
ADJ.part
FOCUS
OFF-SET
2.
Test
mode
2
and
1
3.
FE
(TP-2)/VR5
*A=B
1.
Test
disc
SONY
TYPE
3
(AT-711881)
4.
«Connect
a
digital
DC
voltmeter
to
the
TP
2
(FE)
and
check
the
voltage
A
in
the
test
mode
2,
then
press
STOP
button
and
adjust
the
voltage
B
so
that
the
reading
on
the
digital
DC
voltmeter
is
the
same
as
voltage
A.
|
4
|
TRACKING
SERVO
GAIN
1.
Test
disc
SONY
TYPE
3
(AT-711881)
2.
Test
mode
5
3.
Pi
@pin/
VR4
4.
eConnect
an
oscilloscope
to
the
P1
connector
©
pin.
%*500
to
800mVp-p
[+00
to
SOOmVp-
p
MUSIC
CALENDAR
button
TEST
MODE
|
HOW
TO
SET
EACH
MODE
|
FUNCTION
While
pressing
the
li
and
¢|ndicates
that
unit
is
set
1
PP
buttons,
into
the
TEST
mode.
ON
OFF
OFF
1
insert
the
power
cord.
fe
pe
ea
FADE
AID
Io
oe
2
Press
the
&
OPEN/CLOSE
|
.eocus
SERVO
is
on.
OFF
|
ON
|
OFF.
2
DISC
1
button
~_|
Press
the
&
OPEN/CLOSE
3
*CLV-S
SERVO
is
on.
ON
|
ON
|
OFF
3
[
DISC
2
button
ies
4
Press
the
&
OPEN/CLOSE
|
.
+p
ackING
SERVO
ison.
|
OFF
|
OFF
|
ON
4
DISC
3
button
2
Press
the
PLAY
®
DISC
1
|
*CLV-AandSLEDSERVO
|
oy
|
ore
|
on
-
button
are
on.
6
Press
the
PEAY
P
DISC
2:
|.
SANTI
SHOCKis
on
OFF
|
ON
|
ON
6
E-F
vee
®
[103
¢
ae
OFF—SET,
ie
ee
he
le
Vaan
fe
VR4
TRACKING
GAIN
x
Oo
Ww
=
A
(TP=1)
|
|
|
|
|
|
|
|
1¢1
|
|
|
vb
MAIN
PCB
FRONT
HP
“p!
\
\
eae
v3
|
@
L
FOCUS
SERVO
GAIN
.
Test
disc
SONY
TYPE
3
(AT-711881)
.
Test
mode
5
.
P1®
pin/
VR3
.
«Connect
an
oscilloscope
to
the
P1
connector
pin
*1.0
to
1.4Vp-p
E-F
BALANCE
.
Test
mode
3
.
TE
(TP
2)/VR2
1.
2
3
4
*A=B
Test
disc
SONY
TYPE
3
(AT-711881)
.
eConnect
an
oscilloscope
to
the
TP
2
(TE)
.
Test
mode
1
.
WECK
(TP-1)
/
VR
1
.
eConnect
a
frequency
counter
to
the
TP
1
(WECK).
*7,350
+10Hz
The
disc
tray
can
be
opened
or
closed
by
pressing
the
>
/
mm
button
(during
any
mode).
After
opening
the
tray,
closing
it
will
move
the
pick
up
to
the
inward
position
and
return
the
unit
to
the
TEST
MODE
1.
¢
Pressing
the
@
button
will
return
the
unit
to
the
TEST
MODE
1
regardless
of
the
test
mode
presently
engaged.
However,
the
pick
up
will
not
be
moved.
Test
modes
can
be
selected
directly.
SERVICE”
AA
ANU
A
La
ee
41
CD-650

Related product manuals