Min
Def
Max.
Set Point
–40
0.0
320
Sensor 1 differential
0.1
1.0
20.0
Calibration of probe 1
–20.0
0.0
20.0
Set point upper limit (it cannot be set above this value)
B.I.
99.9
320
Set point lower limit (it cannot be set below this value)
–40.0
–40.0
B.S.
Compressor protection
OFF/ON (From the last disconnection)
ON (to the connection)
OFF/ON
Protection delay time
0
0
255
Compressor ON fault s1
(If it is 0, it will always be stopped)
0
10
255
Compressor OFF fault s1
(If it is 0, it will always be running)
0
5
255
Stop when opening door?
(It requires a digital input configured as door contact)
No
Description
Min
Def
Max.
Defrost type: Electrical heater Reverse cycle
Res
Defrost count: Frequency Compressor sum Real time clock
Fre.
Defrost frequency (Time between two starts)
0
6
120
Defrost duration
0
30
255
Defrost message: Current temperature
Defrost Start temperat
DEFROST message
DEF
Message duration (Time added at the end of the defrost)
0
5
255
Defrost final temperature
–40.0
8.0
99.9
Defrost at Start-up
No
Defrost delay at Start-up
0
0
255
Signals end defrost time
No
Drip time
0
1
255
REFRIGERATION control (Compressor)
DEFROST control
Parameters
SET
........5 seg.
SET SET