1565H041 Ed.03
* See table page 34
**Parameter not available in AKO-15658/59; the AUX relay is configured as “same status compressor”.
Input 1 configuration :
Disabled Door contact External alarm
Severe external alarm Remote defrost Remote energy saving
Low pressure input Thermostat control
Input 1 polarity:
Normally open – The input is activated on closing the contact
Normally closed – The input is activated on opening the contact
Input 2 configuration :
Disabled Door contact External alarm
Severe external alarm Remote defrost Remote energy saving
Low pressure input Thermostat control
Input 2 polarity:
Normally open – The input is activated on closing the contact
Normally closed – The input is activated on opening the contact
Inact. with door open (time)
Aux. relay configuration**: Pump down control Equal compressor state
Pump down duration (0=Deactivated)
Pump down On delay (0=Deactivated)
Press. controller config.:
Combined HP-LP LP indep. AC input
LP indep. digital input
DIGITAL INPUT control
AUXILIARY RELAY control
31