GAS LINE CHANGE (N.G. to LPG, LPG to N.G.)
50
The new gas line and connections must
be selected to be compatible with the
capacity. Follow the below guidelines for
gas line change:
Dismount and keep the measurement
pipe set (No.3) from the nipples and gas
line (this changes according to the gas
line, see Page 22). Dismount the
modulating gas line (2) from the
connection body. Remove the gasket (1)
between the connection body and gas
line. Mount the new gasket (1) (comes
with the new gas line) between the
connection body and gas line flange, use
bolts (6) and washers (5). If the gas line
is a multiblock, remove the plugs
(changes according to the gas line type,
see Page 22) on the connection body
and mount the measurement nipples (8).
Connect the measurement pipe set (7) to
the measurement nipples and to the gas
line (where shown by letters).