2 — 1830 PSS alarms
2-6 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: ChannelPowerUnstable (1996)
Type: communicationsAlarm (4)
Probable cause: OprUnachieve (961)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the optical
power on a channel is unstable.
Name: ClockRedundancy (1997)
Type: equipmentAlarm (3)
Probable cause: SyncSys (980)
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to loss of
clock redundancy in system time.
Name:
ContainingEquipmentAdministrativelyDown
(466)
Type: equipmentAlarm (3)
Probable cause:
containingEquipmentAdministrativelyDown
(330)
Severity: Minor
Object Type (class): Port
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
compositeEquipmentState attribute
has a value of
containingEquipmentAdministrativel
yDown.
Name: ContainingEquipmentMismatch (464)
Type: equipmentAlarm (3)
Probable cause:
containingEquipmentMismatch (328)
Severity: Major
Object Type (class): Port
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
compositeEquipmentState attribute
has a value of
containingEquipmentMismatch.
Name:
ContainingEquipmentOperationallyDown
(465)
Type: equipmentAlarm (3)
Probable cause: containingEquipmentDown
(329)
Severity: Major
Object Type (class): Port
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
compositeEquipmentState attribute
has a value of
containingEquipmentOperationllyDo
wn.
Name:
ControlCardRedundancyCompromised
(1998)
Type: configurationAlarm (11)
Probable cause: SwEqpt (981)
Severity: Minor
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when control
card redundancy is compromised.
Name: DataError (2000)
Type: equipmentAlarm (3)
Probable cause: DataErr (983)
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to dataerror.
Name: DCMInputLOS (1999)
Type: communicationsAlarm (4)
Probable cause: LosDcm (982)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a DCM
raises an input LOS indication.
Name: DiagnosticTerminalLoopbackActive
(2001)
Type: communicationsAlarm (4)
Probable cause: LpbkTerm (984)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a terminal
diagnostic loopback is active.
Name: downgradedCardAlarm (256)
Type: softwareAlarm (19)
Probable cause: downgradedCard (195)
Severity: Warning
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an IOM is
not upgraded or reset after a device
software upgrade of both CPMs. A
device resets an IOM automatically
after 120 minutes if the IOM is not
manually reset after a CPM upgrade.
Alarm Attributes Description
(5 of 37)