Name: CardFailure (1988)
Type: equipmentAlarm (3)
Probable cause: EQPT (972)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the card
fails to communicate.
Name: CardInitializing (1989)
Type: equipmentAlarm (3)
Probable cause: CardInit (973)
Severity: Info
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the card is
initializing.
Name: CardMismatch (1160)
Type: configurationAlarm (11)
Probable cause: CardMismatch (863)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when there is a
mismatch between the provisioned
and actual card types.
Name: CardMissing (1990)
Type: equipmentAlarm (3)
Probable cause: ReplUnitMiss (974)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the card is
missing from the slot.
Name: CardNotAllowed (1991)
Type: equipmentAlarm (3)
Probable cause: CardNotAllowed (975)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to card not
allowed.
Name: CardProvisioningFailure (1992)
Type: equipmentAlarm (3)
Probable cause: DataFlt (976)
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a card
provisioning error is detected.
Name: CardSanityFailure (1993)
Type: configurationAlarm (11)
Probable cause: CardSanity (977)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to card Sanity
failure.
Name:
cardTemperatureAboveOperatingThreshold
(1178)
Type: thresholdCrossed (6)
Probable cause: IntTempHigh (1095)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
temperature of the card raises above
the operating threshold.
Name:
cardTemperatureBelowOperatingThreshold
(1179)
Type: thresholdCrossed (6)
Probable cause: IntTempLow (1096)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
temperature of a card falls below the
operating threshold.
Name: CardUnknown (1994)
Type: equipmentAlarm (3)
Probable cause: Unknown (978)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
software version mismatches.
Name: ChannelPDI (1995)
Type: communicationsAlarm (4)
Probable cause: ChannelPDI (979)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a PDI occurs
on an optical channel.
Alarm Attributes Description