EasyManua.ls Logo

Alcatel-Lucent 5620 - Page 29

Alcatel-Lucent 5620
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 — 1830 PSS alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4 September 2011 2-5
3HE 06513 AAAD TQZZA Edition 01 Optical Alarm Reference
Name: CardFailure (1988)
Type: equipmentAlarm (3)
Probable cause: EQPT (972)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the card
fails to communicate.
Name: CardInitializing (1989)
Type: equipmentAlarm (3)
Probable cause: CardInit (973)
Severity: Info
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the card is
initializing.
Name: CardMismatch (1160)
Type: configurationAlarm (11)
Probable cause: CardMismatch (863)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when there is a
mismatch between the provisioned
and actual card types.
Name: CardMissing (1990)
Type: equipmentAlarm (3)
Probable cause: ReplUnitMiss (974)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the card is
missing from the slot.
Name: CardNotAllowed (1991)
Type: equipmentAlarm (3)
Probable cause: CardNotAllowed (975)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to card not
allowed.
Name: CardProvisioningFailure (1992)
Type: equipmentAlarm (3)
Probable cause: DataFlt (976)
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a card
provisioning error is detected.
Name: CardSanityFailure (1993)
Type: configurationAlarm (11)
Probable cause: CardSanity (977)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to card Sanity
failure.
Name:
cardTemperatureAboveOperatingThreshold
(1178)
Type: thresholdCrossed (6)
Probable cause: IntTempHigh (1095)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
temperature of the card raises above
the operating threshold.
Name:
cardTemperatureBelowOperatingThreshold
(1179)
Type: thresholdCrossed (6)
Probable cause: IntTempLow (1096)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
temperature of a card falls below the
operating threshold.
Name: CardUnknown (1994)
Type: equipmentAlarm (3)
Probable cause: Unknown (978)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
software version mismatches.
Name: ChannelPDI (1995)
Type: communicationsAlarm (4)
Probable cause: ChannelPDI (979)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a PDI occurs
on an optical channel.
Alarm Attributes Description