2 — 1830 PSS alarms
2-4 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: ApsSwitchedToWork (1977)
Type: communicationsAlarm (4)
Probable cause: WkSwBk (962)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on Automatic
switch to working.
Name:
AutLaserOffDuetoUpstreamCondition (1978)
Type: communicationsAlarm (4)
Probable cause: UpstreamFault (963)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a laser
shuts off automatically in response
to an upstream fault condition.
Name:
AutomaticProtectionSwitchToProtection
(1979)
Type: communicationsAlarm (4)
Probable cause: WKSWPR (964)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an
automatic APS switch to the
protection channel occurs.
Name: B1SignalDegrade (1980)
Type: communicationsAlarm (4)
Probable cause: B1Sd (965)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to B1 signal
degrade.
Name: BackplaneBatteryOff (1981)
Type: equipmentAlarm (3)
Probable cause: Pwr (966)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to battery
power at backplane voltage low.
Name: BatteryOff (1982)
Type: equipmentAlarm (3)
Probable cause: Pwr (966)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to battery
off.
Name: BatteryPowerAtBackPlaneOff (1983)
Type: equipmentAlarm (3)
Probable cause:
BatteryPowerAtBackPlaneOff (967)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when battery
power is off at backplane.
Name: BoardEqpt (3338)
Type: equipmentAlarm (3)
Probable cause: BoardEqpt (1171)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a card fails
to initialize.
Name: BothTimingModulesFailed (1984)
Type: configurationAlarm (11)
Probable cause: SyncClkFail (968)
Severity: Critical
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised due system
timing synchronization both units
failed.
Name: CardAbnormalCondition (1985)
Type: communicationsAlarm (4)
Probable cause: cardMan (969)
Severity: Info
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when port/Card
is in maintainence due to abnormal
condition.
Name: CardDegrade (1987)
Type: equipmentAlarm (3)
Probable cause: EqptDgr (971)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the card is
degraded.
Alarm Attributes Description