2 — 1830 PSS alarms
2-10 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: ExcessLoss (3354)
Type: configurationAlarm (11)
Probable cause: ExcessLoss (1187)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the fiber
connection loss is excessive.
Name: FanFailure (624)
Type: equipmentAlarm (3)
Probable cause: fanFailure (116)
Severity: Critical
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
associated fan is not operationally
Up.
Name: FanSpeedHigh (3356)
Type: equipmentAlarm (3)
Probable cause: FanSpeedHigh (1189)
Severity: Minor
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the fan
speed is too high.
Name: FanSpeedLow (3357)
Type: equipmentAlarm (3)
Probable cause: FanSpeedLow (1190)
Severity: Minor
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the fan
speed is too low.
Name: FanSpeedMan (2012)
Type: equipmentAlarm (3)
Probable cause: FanSpeedMan (995)
Severity: Minor
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised due to fan speed
manually set to maximum.
Name: FanSpeedTooHigh (2013)
Type: equipmentAlarm (3)
Probable cause: fanSpeedHigh (996)
Severity: Minor
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the speed
of a fan is too high.
Name: FanSpeedTooLow (2014)
Type: equipmentAlarm (3)
Probable cause: fanSpeedLow (997)
Severity: Minor
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the speed
of a fan is too low.
Name: FanTrayRemoved (569)
Type: equipmentAlarm (3)
Probable cause: FanTrayRemoved (438)
Severity: Critical
Object Type (class): FanTray
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
deviceState attribute has a value of
deviceNotEquipped.
Name: FarEndLocalFault (2015)
Type: communicationAlarm (96)
Probable cause: FELanLFI (998)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a far-end
system detects a local fault.
Name: FarEndLos (2016)
Type: communicationsAlarm (4)
Probable cause: FELOS (999)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised Far End Loss of
Signal.
Name: FarEndLossOfSignal (2017)
Type: communicationAlarm (96)
Probable cause: FELANLOS (1000)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when a far-end
system detects an LOS.