2 — 1830 PSS alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4 September 2011 2-13
3HE 06513 AAAD TQZZA Edition 01 Optical Alarm Reference
Name: InterCardCommsFailure (2036)
Type: equipmentAlarm (3)
Probable cause: ContCom (1020)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the card
fails to communicate.
Name: InterShelfLossofCommunication
(2037)
Type: configurationAlarm (11)
Probable cause: ShelfContCom (1021)
Severity: Critical
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when control
card redundancy is compromised.
Name: IntTempHigh (3360)
Type: equipmentAlarm (3)
Probable cause: IntTempHigh (1095)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a card
reports an over-temperature
condition.
Name: IntTempLow (3361)
Type: equipmentAlarm (3)
Probable cause: IntTempLow (1096)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a card
reports an under-temperature
condition.
Name: IntTempOpt (3362)
Type: equipmentAlarm (3)
Probable cause: IntTempOpt (1047)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an optical
module reports an over-temperature
condition.
Name: InvalidEgress (3363)
Type: configurationAlarm (11)
Probable cause: InvalidEgress (1193)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an egress
port is invalid or undefined.
Name: InvalidThreshold (2038)
Type: configurationAlarm (11)
Probable cause: InvalidThreshold (1022)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to Invalid
Threshold.
Name: InvalidThresholdOms (3364)
Type: configurationAlarm (11)
Probable cause: InvalidThresholdOms (1194)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an OMS
threshold is invalid.
Name: InvalidThresholdOts (3365)
Type: configurationAlarm (11)
Probable cause: InvalidThresholdOts (1195)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an OTS
threshold is invalid.
Name: LaserBackFacetOptPwrTca (3366)
Type: configurationAlarm (11)
Probable cause: LaserBackFacetOptPwrTca
(1196)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the laser
back-facet optical power crosses a
threshold.
Name: LaserCoolingCurTca (3367)
Type: configurationAlarm (11)
Probable cause: LaserCoolingCurTca (1197)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the laser
cooling current crosses a threshold.
Alarm Attributes Description