2 — 1830 PSS alarms
2-12 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: FpgaFailed (2027)
Type: equipmentAlarm (3)
Probable cause: FpgaFail (1010)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due FPGA fails.
Name: FpgaInitialization (2028)
Type: equipmentAlarm (3)
Probable cause: FpgaInit (1011)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due FPGA
initialization.
Name: FpgaTimedout (2029)
Type: equipmentAlarm (3)
Probable cause: FpgaTimeout (1012)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due FPGA times
out.
Name: GFPLossofFrameDelineation (2030)
Type: communicationsAlarm (4)
Probable cause: LFD (1013)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a GFP raises
an LFD.
Name: GFPUserPayloadMismatch (2031)
Type: communicationsAlarm (4)
Probable cause: UPM (1014)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a GFP user
payload mismatch is detected.
Name: HighBER (682)
Type: communicationsAlarm (4)
Probable cause: HiBER (1015)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when BER is high.
Name: HwRevisionNotSupported (2032)
Type: equipmentAlarm (3)
Probable cause: Hwnotsupported (1016)
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to hardware
not supported for current
configuration.
Name: IncomingSupvyLOF (2033)
Type: communicationsAlarm (4)
Probable cause: LOF (1017)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when Incoming
SUPVY detects an LOF.
Name: IncomingSupvyLOS (2034)
Type: communicationsAlarm (4)
Probable cause: LOS (1018)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when Incoming
SUPVY detects LOS.
Name: IncompatFan (3359)
Type: equipmentAlarm (3)
Probable cause: IncompatFan (1192)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an
incompatible fan is detected.
Name: InputVoltageUnstable (2035)
Type: equipmentAlarm (3)
Probable cause: VoltageUnstable (1019)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the input
voltage is unstable.