2 — 1830 PSS alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4 September 2011 2-15
3HE 06513 AAAD TQZZA Edition 01 Optical Alarm Reference
Name: LossofSignal (2044)
Type: communicationsAlarm (4)
Probable cause: LOS (1018)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the loss of
signal occurs.
Name: LossofSynchronization (2045)
Type: communicationAlarm (96)
Probable cause: FeLanLss (1028)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a far-end
system detects a loss of
synchronization.
Name: LossTooHigh (3373)
Type: configurationAlarm (11)
Probable cause: OprLossHigh (1044)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the optical
loss is above the operational range.
Name: LossTooLow (2042)
Type: configurationAlarm (11)
Probable cause: OprLossLow (1027)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the optical
loss is below the operational range.
Name: LostBothClks (2046)
Type: equipmentAlarm (3)
Probable cause: SyncSysOos (1029)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to using of
local oscilator for system time..
Name: LostPri (2047)
Type: equipmentAlarm (3)
Probable cause: Sync (1030)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to loss of
primary line.
Name: LostSec (2048)
Type: equipmentAlarm (3)
Probable cause: Sync (1030)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to loss of
secondary line.
Name:
ManualProtectionSwitchToProtection (2049)
Type: communicationsAlarm (4)
Probable cause: ManWKSWPR (1031)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a manual
APS switch to the protection channel
occurs.
Name: ManualProtectionSwitchToWorking
(2050)
Type: communicationsAlarm (4)
Probable cause: ManWKSWbk (1032)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a manual
APS switch to the working channel
occurs.
Name: MismatchFiber (3374)
Type: configurationAlarm (11)
Probable cause: MismatchFiber (1203)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a
mismatched fiber connection is
detected.
Name: MissingWaveKeyRaised (3375)
Type: communicationsAlarm (4)
Probable cause: LosOut (1204)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when fiber link
gets cut/disconnected.
Alarm Attributes Description
(14 of 37)