2 — 1830 PSS alarms
2-16 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: MixedPFUsed (3376)
Type: configurationAlarm (11)
Probable cause: MixedPFUsed (1205)
Severity: Critical
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when mixed types
of power filters are in use.
Name: ModulatorOutputPowerOutOfRange
(2051)
Type: communicationsAlarm (4)
Probable cause: ModOutOfRange (1033)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on Modulator
Output Power OutOfRange.
Name: MonitorFailure (2052)
Type: equipmentAlarm (3)
Probable cause: Mismatch (1034)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to card
degrade.
Name: Msim (3377)
Type: configurationAlarm (11)
Probable cause: Msim (1206)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a multiplex
structure identifier mismatch is
detected.
Name: OaPumpBiasCurrHigh (2061)
Type: equipmentAlarm (3)
Probable cause: OaPumpBiasCurrHigh
(1042)
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to optical
amplifier pum laser bias current
high.
Name: OaPumpTempHigh (2062)
Type: equipmentAlarm (3)
Probable cause: OaPumpTempHigh (1043)
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to optical
amplifier pump laser temperature
high.
Name: OduAis (3379)
Type: configurationAlarm (11)
Probable cause: OduAis (1208)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an ODU
reports an AIS.
Name: OduAisEgress (3380)
Type: configurationAlarm (11)
Probable cause: OduAisEgress (1209)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an ODU
reports an egress AIS.
Name: ODUBackwardDefectIndication
(2053)
Type: communicationsAlarm (4)
Probable cause: BDI (1035)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a BDI is
received.
Name: ODUEgressLocked (2054)
Type: communicationsAlarm (4)
Probable cause: Locked (1036)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an ODU is
locked.
Name: ODUEgressSignalDegrade (2055)
Type: communicationsAlarm (4)
Probable cause: SgnlDegrade (1037)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when signal
degradation is detected.
Alarm Attributes Description
(15 of 37)