2 — 1830 PSS alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4 September 2011 2-17
3HE 06513 AAAD TQZZA Edition 01 Optical Alarm Reference
Name: ODUOpenConnectionIndication
(2056)
Type: communicationsAlarm (4)
Probable cause: OCI (1038)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an ODU
detects an OCI.
Name: ODUPayloadMismatchIndication
(2057)
Type: configurationAlarm (11)
Probable cause: PayloadMismatch (1039)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an ODU
detects a payload mismatch.
Name: OperationLossRangeHigh (2063)
Type: communicationsAlarm (4)
Probable cause: OprLossHigh (1044)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
operational loss range too high.
Name: oprLossTooLow (3556)
Type: communicationsAlarm (4)
Probable cause: OprLossLow (1027)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to out of
operational range loss too low.
Name: OprPwrHigh (3381)
Type: configurationAlarm (11)
Probable cause: OprPwrHigh (1210)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
operational input power is too high.
Name: OprPwrLow (3382)
Type: configurationAlarm (11)
Probable cause: OprPwrLow (1211)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
operational input power is too low.
Name: OprTx (3383)
Type: configurationAlarm (11)
Probable cause: OprTx (1212)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the power
on an optical channel is unstable.
Name: OpticalPowerReceivedOutOfRange
(2064)
Type: communicationsAlarm (4)
Probable cause: OprOutOfRange (1045)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on Optical power
received out of range.
Name: OpticsModuleMismatch (2065)
Type: configurationAlarm (11)
Probable cause: MismatchMod (1046)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when there is a
mismatch between the provisioned
and actual optical module types.
Name: OpticsModuleUnknown (3386)
Type: configurationAlarm (11)
Probable cause: UnknownMod (1215)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when there is a
mismatch between the provisioned
and actual optical module types.
Name: OpticsOverTemperature (2066)
Type: equipmentAlarm (3)
Probable cause: IntTempOpt (1047)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the optics is
above operational temperature.
Alarm Attributes Description
(16 of 37)