2 — 1830 PSS alarms
2-18 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: OptIntDet (3384)
Type: configurationAlarm (11)
Probable cause: OptIntDet (1213)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an optical
intrusion is detected.
Name: OptIntSusp (3385)
Type: configurationAlarm (11)
Probable cause: OptIntSusp (1214)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when optical
intrusion monitoring is suspended.
Name: OSPFADJ (3378)
Type: configurationAlarm (11)
Probable cause: OSPFADJ (1207)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an OSPF
adjacency is not a full adjacency.
Name: OtuAisAlarm (2067)
Type: communicationsAlarm (4)
Probable cause: OtuAIS (1048)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to trnasmit
laser off.
Name: OTULossofFrame (2058)
Type: communicationsAlarm (4)
Probable cause: LOF (1017)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an OTU LOF
signal is detected.
Name: OTULossofMultiFrame (2059)
Type: communicationsAlarm (4)
Probable cause: LOM (1040)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an OTU LOM
signal is detected.
Name: OTUServerSignalFailure (2060)
Type: communicationsAlarm (4)
Probable cause: ssf (1041)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an OTU
server signal failure occurs.
Name: OutgoingChannelPowerOutofRange
(2068)
Type: communicationsAlarm (4)
Probable cause: OpwrOutOfRange (1049)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the optical
power of a channel is out of range.
Name: PCSGeneratorActive (3387)
Type: configurationAlarm (11)
Probable cause: PCSGeneratorActive (1216)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the PCS
generator activates.
Name: PluggableModeuleSeepFailure (2069)
Type: communicationsAlarm (4)
Probable cause: FactTermDev (1050)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an SFP
module fails.
Name: PortFailure (2070)
Type: communicationsAlarm (4)
Probable cause: EqupPort (1051)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the port
failure occurs.
Alarm Attributes Description
(17 of 37)