2 — 1830 PSS alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4 September 2011 2-19
3HE 06513 AAAD TQZZA Edition 01 Optical Alarm Reference
Name: PortTransmissionDegrade (2071)
Type: communicationsAlarm (4)
Probable cause: LsrOutDgr (1052)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to port
transmit degrade.
Name: PortTransmissionFailure (3388)
Type: communicationsAlarm (4)
Probable cause: Trmt (1217)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the port
Transmission failure occurs.
Name: PowerAdjustmentFailure (2072)
Type: communicationsAlarm (4)
Probable cause: PwrAdjFail (1053)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the power
adjustment fails.
Name: PowerAdjustmentRequired (2073)
Type: communicationsAlarm (4)
Probable cause: PwrAdjReq (1054)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the power
adjustment requires.
Name: PowerFilterMismatch (2074)
Type: configurationAlarm (11)
Probable cause: PowerFilterMismatch
(1055)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when mismatch
in power filter.
Name: PowerFilterOff (2075)
Type: equipmentAlarm (3)
Probable cause: PowerIssue (1056)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when Power
filter/Battery is off or low voltage.
Name: PowerManagementSuspended (2076)
Type: communicationsAlarm (4)
Probable cause: PwrSusp (1057)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when power
management is suspended.
Name: PowerManagementTopologyIssue
(2077)
Type: communicationsAlarm (4)
Probable cause: PinvalidTopo (1058)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the power
management topology is invalid.
Name: ProtectionLockout (2078)
Type: communicationsAlarm (4)
Probable cause: LockOutOfPR (1059)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an APS
lockout of the protection channel
occurs.
Name:
ProtectionSwitchingEquipmentFailure
(2079)
Type: equipmentAlarm (3)
Probable cause: RcvrOptProg (1060)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
protection switching equipment
fails.
Name: ProtectionSwitchingFail (2080)
Type: communicationsAlarm (4)
Probable cause: ApsProtSWFail (1061)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when Protection
switching fails.
Alarm Attributes Description
(18 of 37)