2 — 1830 PSS alarms
2-20 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: PwrMaxGain (2081)
Type: configurationAlarm (11)
Probable cause: PwrMaxGain (1062)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on Gain
Adjustment Exceeded Max Value.
Name: PwrTiltSusp (3389)
Type: configurationAlarm (11)
Probable cause: PwrTiltSusp (1218)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when amplifier
gain tilt adjustments are suspended.
Name: PwrUnbalance (3390)
Type: configurationAlarm (11)
Probable cause: PwrUnbalance (1219)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a general
power imbalance is detected.
Name: PwrUnbalanceOms (3391)
Type: configurationAlarm (11)
Probable cause: PwrUnbalanceOms (1220)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an OMS
power imbalance is detected.
Name: RamanSupAlarm (2082)
Type: configurationAlarm (11)
Probable cause: RAMANSUP (1063)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to Raman
Suppress - Line
Name: RcvrOptProg (2083)
Type: equipmentAlarm (3)
Probable cause: RcvrOptProg (1060)
Severity: Minor
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to receiver
optimization in progress.
Name: RemoteClientLocalFault (2084)
Type: communicationsAlarm (4)
Probable cause: LfiEgr (1064)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a remote
client detects a local fault.
Name: RemoteFault (2085)
Type: communicationsAlarm (4)
Probable cause: LanRfi (1065)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a remote
fault is detected.
Name: ReplUnitMissMOD (3392)
Type: configurationAlarm (11)
Probable cause: ReplUnitMissMOD (1221)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a pluggable
module is missing.
Name: SfpEOLAlarm (2087)
Type: communicationsAlarm (4)
Probable cause: sfpEOL (1067)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on SFP or XFP
Laser end of life.
Name: SfpTempOOR (2088)
Type: communicationsAlarm (4)
Probable cause: SfpTempOOR (1068)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
SFP or XFP laser temperature out of
range
Alarm Attributes Description
(19 of 37)