2 — 1830 PSS alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4 September 2011 2-21
3HE 06513 AAAD TQZZA Edition 01 Optical Alarm Reference
Name: SfpTrmtPwrOORAlarm (2089)
Type: communicationsAlarm (4)
Probable cause: SfpTrmtPwrOOR (1069)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on SFP or XFP
optical transmit power out of range.
Name: ShelfMismatch (2090)
Type: configurationAlarm (11)
Probable cause: ShelfMismatch (1070)
Severity: Critical
Object Type (class): Shelf
Domain: equipment
Implicitly cleared (self-clearing): No
The alarm is raised when the shelf
mismatches.
Name: SignalDegrade (2091)
Type: communicationsAlarm (4)
Probable cause: Deg (1071)
Severity: Major
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on Signal Degrade
Egress - ODU.
Name: SoftwareVersionMismatch (2092)
Type: equipmentAlarm (3)
Probable cause: SfMismatch (1072)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
software version mismatches.
Name: SonetLossOfFrame (2093)
Type: communicationsAlarm (4)
Probable cause: Lof (1073)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to loss of
frame.
Name: SonetSectionTraceMismatch (2094)
Type: communicationsAlarm (4)
Probable cause: Tim (1074)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to mismatch
in trace identifierl.
Name: SpLoAdjFail (3393)
Type: configurationAlarm (11)
Probable cause: SpLoAdjFail (1222)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a span loss
adjustment failure is detected.
Name: SUPVYSignalDegrade (2086)
Type: communicationsAlarm (4)
Probable cause: SignalDegrade (1066)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when SUPVY
signal degradation is detected.
Name: SwitchingMatrixModuleFails (2095)
Type: communicationsAlarm (4)
Probable cause: SwmTxMod (1075)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a switching
matrix module fails.
Name: SystemTimeCardMismatch (2096)
Type: equipmentAlarm (3)
Probable cause: Mismatch (1034)
Severity: Critical
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to system
timing card mismatch.
Name: TBbeMs15Min (3396)
Type: configurationAlarm (11)
Probable cause: T_BBE_MS_15MIN (1225)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the BBE-MS
15-minute threshold is crossed.
Alarm Attributes Description