2 — 1830 PSS alarms
2-22 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: TBbeMs1Day (3397)
Type: configurationAlarm (11)
Probable cause: T_BBE_MS_1DAY (1226)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the BBE-MS
one-day threshold is crossed.
Name: TBbeOdu15Min (3398)
Type: configurationAlarm (11)
Probable cause: T_BBE_ODU_15MIN (1227)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
BBE-ODU 15-minute threshold is
crossed.
Name: TBbeOdu1Day (3399)
Type: configurationAlarm (11)
Probable cause: T_BBE_ODU_1DAY (1228)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
BBE-ODU one-day threshold is
crossed.
Name: TBbeOtu15Min (3400)
Type: configurationAlarm (11)
Probable cause: T_BBE_OTU_15MIN (1229)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
BBE-OTU 15-minute threshold is
crossed.
Name: TBbeOtu1Day (3401)
Type: configurationAlarm (11)
Probable cause: T_BBE_OTU_1DAY (1230)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
BBE-OTU one-day threshold is
crossed.
Name: TBbeP15Min (3402)
Type: configurationAlarm (11)
Probable cause: T_BBE_P_15MIN (1231)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the BBE-P
15-minute threshold is crossed.
Name: TBbeP1Day (3403)
Type: configurationAlarm (11)
Probable cause: T_BBE_P_1DAY (1232)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the BBE-P
one-day threshold is crossed.
Name: TBbePt15Min (3404)
Type: configurationAlarm (11)
Probable cause: T_BBE_PT_15MIN (1233)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the BBE-PT
15-minute threshold is crossed.
Name: TBbePt1Day (3405)
Type: configurationAlarm (11)
Probable cause: T_BBE_PT_1DAY (1234)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the BBE-PT
one-day threshold is crossed.
Name: TBbeRs15Min (3406)
Type: configurationAlarm (11)
Probable cause: T_BBE_RS_15MIN (1235)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the BBE-RS
15-minute threshold is crossed.
Name: TBbeRs1Day (3407)
Type: configurationAlarm (11)
Probable cause: T_BBE_RS_1DAY (1236)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the BBE-RS
one-day threshold is crossed.
Alarm Attributes Description
(21 of 37)