2 — 1830 PSS alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4 September 2011 2-27
3HE 06513 AAAD TQZZA Edition 01 Optical Alarm Reference
Name: TEthpkter15Min (3450)
Type: configurationAlarm (11)
Probable cause: T_ETHPKTER_15MIN (1279)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
ETHPKTER 15-minute threshold is
crossed.
Name: TEthpkter1Day (3451)
Type: configurationAlarm (11)
Probable cause: T_ETHPKTER_1DAY (1280)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
ETHPKTER one-day threshold is
crossed.
Name: TEthpktert15Min (3452)
Type: configurationAlarm (11)
Probable cause: T_ETHPKTERT_15MIN
(1281)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
ETHPKTERT 15-minute threshold is
crossed.
Name: TEthpktert1Day (3453)
Type: configurationAlarm (11)
Probable cause: T_ETHPKTERT_1DAY (1282)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
ETHPKTERT one-day threshold is
crossed.
Name: TFeBbeMs15Min (3454)
Type: configurationAlarm (11)
Probable cause: T_FEBBE_MS_15MIN (1283)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
FEBBE-MS 15-minute threshold is
crossed.
Name: TFeBbeMs1Day (3455)
Type: configurationAlarm (11)
Probable cause: T_FEBBE_MS_1DAY (1284)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
FEBBE-MS one-day threshold is
crossed.
Name: TFeBbeOdu15Min (3456)
Type: configurationAlarm (11)
Probable cause: T_FEBBE_ODU_15MIN
(1285)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FarEnd
BBE-ODU 15-minute threshold is
crossed.
Name: TFeBbeOdu1Day (3457)
Type: configurationAlarm (11)
Probable cause: T_FEBBE_ODU_1DAY (1286)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FarEnd
BBE-ODU one-day threshold is
crossed.
Name: TFeBbeOtu15Min (3458)
Type: configurationAlarm (11)
Probable cause: T_FEBBE_OTU_15MIN
(1287)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FarEnd
BBE-OTU 15-minute threshold is
crossed.
Name: TFeBbeOtu1Day (3459)
Type: configurationAlarm (11)
Probable cause: T_FEBBE_OTU_1DAY (1288)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FarEnd
BBE-OTU one-day threshold is
crossed.
Name: TFecc15Min (3480)
Type: configurationAlarm (11)
Probable cause: T_FECC_15MIN (1309)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FECC
15-minute threshold is crossed.
Alarm Attributes Description
(26 of 37)