2 — 1830 PSS alarms
2-28 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: TFecc1Day (3481)
Type: configurationAlarm (11)
Probable cause: T_FECC_1DAY (1310)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FECC
one-day threshold is crossed.
Name: TFecUbu15Min (3478)
Type: configurationAlarm (11)
Probable cause: T_FEC_UBU_15MIN (1307)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FEC
UBU 15-minute threshold is crossed.
Name: TFecUbu1Day (3479)
Type: configurationAlarm (11)
Probable cause: T_FEC_UBU_1DAY (1308)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FEC
UBU one-day threshold is crossed.
Name: TFeEsMs15Min (3460)
Type: configurationAlarm (11)
Probable cause: T_FEES_MS_15MIN (1289)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FEES-MS
15-minute threshold is crossed.
Name: TFeEsMs1Day (3461)
Type: configurationAlarm (11)
Probable cause: T_FEES_MS_1DAY (1290)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FEES-MS
one-day threshold is crossed.
Name: TFeEsOdu15Min (3462)
Type: configurationAlarm (11)
Probable cause: T_FEES_ODU_15MIN (1291)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FarEnd
ES-ODU 15-minute threshold is
crossed.
Name: TFeEsOdu1Day (3463)
Type: configurationAlarm (11)
Probable cause: T_FEES_ODU_1DAY (1292)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FarEnd
ES-ODU one-day threshold is crossed.
Name: TFeEsOtu15Min (3464)
Type: configurationAlarm (11)
Probable cause: T_FEES_OTU_15MIN (1293)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FarEnd
ES-OTU 15-minute threshold is
crossed.
Name: TFeEsOtu1Day (3465)
Type: configurationAlarm (11)
Probable cause: T_FEES_OTU_1DAY (1294)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the FarEnd
ES-OTU one-day threshold is crossed.
Name: TFeSesMs15Min (3466)
Type: configurationAlarm (11)
Probable cause: T_FESES_MS_15MIN (1295)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
FESES-MS 15-minute threshold is
crossed.
Name: TFeSesMs1Day (3467)
Type: configurationAlarm (11)
Probable cause: T_FESES_MS_1DAY (1296)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
FESES-MS one-day threshold is
crossed.
Alarm Attributes Description
(27 of 37)