2 — 1830 PSS alarms
2-36 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Name: TUasP1Day (3539)
Type: configurationAlarm (11)
Probable cause: T_UAS_P_1DAY (1368)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the UAS-P
one-day threshold is crossed.
Name: TUasPt15Min (3540)
Type: configurationAlarm (11)
Probable cause: T_UAS_PT_15MIN (1369)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the UAS-PT
15-minute threshold is crossed.
Name: TUasPt1Day (3541)
Type: configurationAlarm (11)
Probable cause: T_UAS_PT_1DAY (1370)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the UAS-PT
one-day threshold is crossed.
Name: TUasRs15Min (3542)
Type: configurationAlarm (11)
Probable cause: T_UAS_RS_15MIN (1371)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the UAS-RS
15-minute threshold is crossed.
Name: TUasRs1Day (3543)
Type: configurationAlarm (11)
Probable cause: T_UAS_RS_1DAY (1372)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the UAS-RS
one-day threshold is crossed.
Name: TUasRst15Min (3544)
Type: configurationAlarm (11)
Probable cause: T_UAS_RST_15MIN (1373)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the UAS-RS
15-minute threshold is crossed.
Name: TUasRst1Day (3545)
Type: configurationAlarm (11)
Probable cause: T_UAS_RST_1DAY (1374)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the UAS-RS
one-day threshold is crossed.
Name: TunableLaserNotProvisioned (2108)
Type: configurationAlarm (11)
Probable cause: PrcdrErr (1083)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised on Tunable laser
not provisioned.
Name: UnExpectedWaveKey (2109)
Type: communicationsAlarm (4)
Probable cause: OchUnknown (1084)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
unaccepted wave key occurs.
Name: UnitFail (2110)
Type: equipmentAlarm (3)
Probable cause: SyncClk (1085)
Severity: Major
Object Type (class): CardSlot
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised due to system
timing synchronization unit failed.
Name: UnknowWaveKeyForConnection
(2111)
Type: communicationsAlarm (4)
Probable cause: OWN (1086)
Severity: Minor
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
unknown och trail for cross-connect.