2 — 1830 PSS alarms
Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4 September 2011 2-37
3HE 06513 AAAD TQZZA Edition 01 Optical Alarm Reference
Name: upgradedCardAlarm (255)
Type: softwareAlarm (19)
Probable cause: upgradedCard (194)
Severity: Warning
Object Type (class): Card
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the standby
CPM is rebooted and operational
after a software upgrade. A device
resets an IOM automatically after 120
minutes if the IOM is not manually
reset after a CPM upgrade.
Name: UpstreamChannelCollision (2112)
Type: communicationsAlarm (4)
Probable cause: ChanColl (1087)
Severity: Info
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a collision
in one upstream channel is detected.
Name: UruOchLos (3547)
Type: configurationAlarm (11)
Probable cause: UruOchLos (1377)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
underlying channel is unavailable
because of an LOS.
Name: UruOmsRx (3548)
Type: configurationAlarm (11)
Probable cause: UruOmsRx (1378)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
underlying ingress OMS is
unavailable.
Name: UruOtsLos (3549)
Type: configurationAlarm (11)
Probable cause: UruOtsLos (1379)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
underlying OTS is unavailable
because of an LOS.
Name: UruOtsRx (3550)
Type: configurationAlarm (11)
Probable cause: UruOtsRx (1380)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
underlying ingress OTS is
unavailable.
Name: UruOtsTx (3551)
Type: configurationAlarm (11)
Probable cause: UruOtsTx (1381)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
underlying egress OTS is unavailable.
Name: UruOtu (3552)
Type: configurationAlarm (11)
Probable cause: UruOtu (1382)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an
underlying OTU is unavailable.
Name: UruS (3553)
Type: configurationAlarm (11)
Probable cause: UruS (1383)
Severity: Warning
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when an
underlying resource is unavailable.
Name: VCGLossofAlignment (2113)
Type: communicationsAlarm (4)
Probable cause: VCGLoA (1088)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a VCG loss
of alignment is detected.
Name: VCGServerSignalFailure (2114)
Type: communicationsAlarm (4)
Probable cause: LossofSignal (1089)
Severity: Critical
Object Type (class): PhysicalPort
Domain: equipment
Implicitly cleared (self-clearing): Yes
The alarm is raised when a VCG
server detects a signal failure.
Alarm Attributes Description