2 — 1830 PSS alarms
2-42 September 2011 Alcatel-Lucent 5620 Service Aware Manager, Release 9.0 R4
Optical Alarm Reference 3HE 06513 AAAD TQZZA Edition 01
Table 2-3 Domain: optical
Name: UpgradedBuildVersionMismatch
(174)
Type: configurationAlarm (11)
Probable cause: upgradedImageNotBooted
(137)
Severity: Warning
Object Type (class):
NetworkElement
Domain: netw
Implicitly cleared (self-clearing): Yes
The alarm is raised when the
software version that an NE reports
after a software upgrade does not
match the version of the software
used for the upgrade.
Name: WrongCpaaSoftwareVersion (791)
Type: equipmentAlarm (3)
Probable cause: wrongCpaaSoftwareVersion
(559)
Severity: Critical
Object Type (class):
NetworkElement
Domain: netw
Implicitly cleared (self-clearing): Yes
The alarm is raised when the 7701
CPAA software is the wrong version
and requires an upgrade.
Alarm Attributes Description
Name: AISLine (2902)
Type: communicationAlarm (96)
Probable cause: LossofSignal (1089)
Severity: Info
Object Type (class):
OpticalPortSpecifics
Domain: optical
Implicitly cleared (self-clearing): No
The alarm is raised when the sonet
alarm indication occurs.
Name: ExcessiveBER (2903)
Type: communicationAlarm (96)
Probable cause: LossofSignal (1089)
Severity: Critical
Object Type (class):
OpticalPortSpecifics
Domain: optical
Implicitly cleared (self-clearing): No
The alarm is raised when the sonet
signal fails.
Name: RFILine (2904)
Type: communicationAlarm (96)
Probable cause: LossofSignal (1089)
Severity: Info
Object Type (class):
OpticalPortSpecifics
Domain: optical
Implicitly cleared (self-clearing): No
The alarm is raised when the sonet
remote line fails.
Name: SignalDegrade (2091)
Type: communicationAlarm (96)
Probable cause: LossofSignal (1089)
Severity: Major
Object Type (class):
OpticalPortSpecifics
Domain: optical
Implicitly cleared (self-clearing): No
The alarm is raised when the sonet
singnal degrades.
Name: SonetLossofSingal (2905)
Type: communicationAlarm (96)
Probable cause: LossofSignal (1089)
Severity: Critical
Object Type (class):
OpticalPortSpecifics
Domain: optical
Implicitly cleared (self-clearing): No
The alarm is raised when sonet/sdh
loss of signal occurs.
Name: SystemModeChange (1923)
Type: equipmentAlarm (3)
Probable cause: systemModeChange (923)
Severity: Major
Object Type (class):
OpticalNeProperties
Domain: optical
Implicitly cleared (self-clearing): No
The alarm is raised when an NE
undergoes a system mode change,
for ex. from SONET to SDH mode.
The alarm information includes the
Site ID, old system mode value and
new system mode value.