Type Message Location Additional Information Action
105 PERMANENT BOARD RESET Board loca-
tion.
INFO 0 =1: hardware fault; 2: no re-
sponse from board; 3: fan failure; 4:
running on battery; 5: license prob-
lem; 6: maintenance problem; 7:
reason unknown; 8: power supply
problem
INFO 1 = cause of reset
Disconnect
and reconnect
the board. If
the fault per-
sists, replace
the board
106 BOARD REFUSED
The board has been refused
and, in the case of an intelligent
board, a permanent reset is per-
formed on it
Board loca-
tion
INFO 0 = type of board
INFO 1 = cause of refusal: (See
Reasons for board refusal (INFO 1
of message 106) )
1: REJ_MAX_BRD_POW: Too
much power consumed
4: REJ_UNKOWN_BOARD_TYPE:
Board unknown by system
5: REJ_BOARD_FORBIDDEN:
Board known, but not allowed at
that location
6:
REJ_PRA_IN_MASTER_NEEDED:
No PRA access in Master cabinet
7: REJ_NO_LICENSE: Not Accep-
ted according rights given by the Li-
cense
8: REJ_TOO_MANY_CPUS: Max
of Applicative boards is reached
9: REJ_BOARD_INIT_FAILED:
Board could not be initialized
13: REJ_TOO_MANY_RAS: Max of
coCPU RAS boards is reached
15:
REJ_NO_MORE_MIXED_BOARD_
LICENSE: Number of trunks on
Mixed board reaches maximum giv-
en by the license
Check the
hardware
configuration
(the system
limits may
have been ex-
ceeded).
107 MMC BOARD RESET
The reset of an interface board
processor has been requested
by MMC
Board loca-
tion
108 POWER OFF: LAUNCH OF
BACKUP PROCEDURE FOR A
BOARD
Board loca-
tion
109 BOARD INFO CLEARED BY
OMC
Board loca-
tion
Chapter
6
% *
34/62
 ! "#$ ! % $& !     