Mounting the Switch OmniSwitch 6850 Series Chassis and Hardware Components
page 2-62 OmniSwitch 6850 Series Hardware Users Guide August 2007
3 After the rack-mount flanges are secured to the chassis, mark the holes on the rack where the switch is
to be installed.
4 Lift and position the switch until the rack-mount flanges are flush with the rack post.
5 Align the holes in the flanges with the rack holes that were marked in step 3.
6 Once the holes are aligned, insert a rack mount screw (not provided) through the bottom hole of each
flange. Tighten both screws until they are secure.
Attaching the Switch to the Rack
Note. Be sure to install the screws in the bottom hole of each flange, as shown, before proceeding.
7 Once the screws at the bottom of each flange are secure, install the remaining two rack mount screws.
Be sure that all screws are securely tightened.
Note. If you are installing multiple switches in a rack to form a stacked configuration, refer to “Setting Up
a Stacked Configuration” on page 2-63.
Installing and Removing Combo Port SFPs
OmniSwitch 6850 Series switches offer four Gigabit Ethernet combo, located on the front panel (see page
2-23). These combo support hot-swappable fiber Small Form-Factor Pluggables (SFPs). For instructions
on installing and removing combo connector SFPs, refer to the instruction card provided with the SFP
product.
Note. Combo port preferences are user-configurable via the system software. Refer to the “Configuring
Ethernet” in the OmniSwitch 6850 Series Network Configuration Guide for complete details.