Loading...
AOS Release 6.4.6.R01 Release Notes November 2013
Open Problem Reports and Feature Exceptions
in Release 6.4.6.R01
The problems listed here include problems known at the time of the product’s release. Any problems not
discussed in this section should be brought to the attention of the Alcatel-Lucent Technical Support
organization as soon as possible. Please contact customer support for updates on problem reports (PRs)
where no known workaround was available at the time of release.
LAYER 2
Autoneg
PR
Description
Workaround
186066
When a combo fiber port on an OmniSwitch 6850E (with
auto-negotiation disabled) is connected to any other
OmniSwitch which also has auto-negotiation disabled, the
port does not come up even after reloading the
OmniSwitch 6850E.
Disable auto negotiation for both
fiber and copper combo ports
instead of just the fiber port.
Multicast
PR
Description
Workaround
187957
Mulitcast source entries are missing on receiver side after
admin down of primary member port of a linkagg. The
issue is observed only if the linkagg member ports are on
different NIs and the admin down of the primary port is
done which is closer to the multicast source. In a cable
fault scenario (Physical cable pull) issue is not seen.
Disable and re-enable the linkagg.
QoS
QoS
PR
Description
Workaround
186114
Traffic gets dropped when QoS port ingress
bandwidth is configured during run-time after policy
rule for UNP profile .
There is no known workaround at
this time.
SIP
PR
Description
Workaround
177082/184466
DSCP marking based on local SIP QoS rule is
not carried on egress packets towards EDGE
endpoint when call server reachability (uplink
port) and edge port is on different NI. Also
statistics are not updated when endpoints are
Configure the edge port as part
of Linkagg.
OmniSwitch 6850E/6855/9000E------ Release 6.4.6.R01 Page 37 of 80