AOS Release 6.4.6.R01 Release Notes November 2013
Appendix D: Required Minimum Uboot for
Modules with New Flash Component
The modules listed below are being manufactured with a new flash component that requires a minimum Uboot
version. The new modules will be shipped with the proper Uboot installed and should not be downgraded when
deploying them into an existing network. These modules are fully compatible with all previous AOS Releases in
which they were initially supported.
The modules listed below have different uboot/miniboot requirements than modules with the previous flash
components. Please review the upgrade instructions prior to upgrading to AOS Release 6.4.6.R01.
Note: If one of the modules listed below is downgraded to an unsupported Uboot version it must be
returned to Alcatel-Lucent for repair.
Identifying the New Modules:
1. New 9000 level part number as listed below.
2. Minimum Uboot revision sticker on the module when shipped.
Module Identification Example using CLI
-> show ni 1
Module in slot 1
Model Name: OS9700-24E,
Description: C24 10/100/1000,
Part Number: 903184-90,
Hardware Revision: C15,
Serial Number: G25Q0772,
Manufacture Date: JUN 28 2012,
Firmware Version: ,
Admin Status: POWER ON,
Operational Status: UP,
Power Consumption: 51,
Power Control Checksum: 0xd872,
CPU Model Type : Motorola MPC8540 ADS,
MAC Address: 00:d0:95:ec:d1:c8,
ASIC - Physical 1: BCM56504_A1,
FPGA - Physical 1: 0005/00,
UBOOT Version : 6.4.4.506.R01,
UBOOT-miniboot Version : No Miniboot,
POE SW Version : n/a
OmniSwitch 6850E/6855/9000E------ Release 6.4.6.R01 Page 67 of 80