What does error D08 no connect mean on my Alcatel Vacuum Technology Adixen ATP 400 Water Pump?
- EEddie PatrickSep 9, 2025
If the Alcatel Vacuum Technology Water Pump displays 'D08 : NO CONNECT', check the cable connection to the pump.
What does error D08 no connect mean on my Alcatel Vacuum Technology Adixen ATP 400 Water Pump?
If the Alcatel Vacuum Technology Water Pump displays 'D08 : NO CONNECT', check the cable connection to the pump.
What does error D26 no connect mean on my Alcatel Vacuum Technology Adixen ATP 400 Water Pump?
If the Alcatel Vacuum Technology Water Pump displays 'D26 : NO CONNECT', check the cable controller electrical connection.
What does error D02 DLY software mean on my Alcatel Vacuum Technology Adixen ATP 400?
If the Alcatel Vacuum Technology Water Pump displays 'D02 : DLY SOFTWARE' due to a soft counter default, reinitialize the controller with the main switch (0/1).
What does error D01 EXT safety mean on my Alcatel Vacuum Technology Water Pump?
If the Alcatel Vacuum Technology Water Pump displays 'D01 : EXT SAFETY' because the external security contact on the REMOTE CONTROL connector is activated, test the external safety devices (contact 31 - 32); repair the fault and press START to restart.
Brand | Alcatel Vacuum Technology |
---|---|
Model | Adixen ATP 400 |
Category | Water Pump |
Language | English |
Explains the fundamental operating mechanism of turbomolecular pumps.
Provides detailed specifications and performance data for ATP pumps.
Essential safety guidelines before operating or installing the pump.
How to physically connect the pump to the vacuum installation.
Wiring procedures for ACT 200 T and 600 T controllers.
Step-by-step guide for starting up ACT 200 T and 600 T controllers.
Step-by-step guide for starting up the ACT 1000 T controller.
Initial startup procedures and crucial safety instructions.
How to operate the pump in a vacuum application.
Troubleshooting guide for ACT 200 T and 600 T controllers.
Troubleshooting guide for the ACT 1000 T controller.
Safety measures and precautions before performing maintenance.
Step-by-step guide for replacing bearings in ATP 80/100 pumps.
Step-by-step guide for replacing bearings in ATP 150/400/900.
Running-in procedure for ATP 80, 100, 150, and 400 pumps.
Running-in procedure specifically for the ATP 900 pump.