ATP SERIES
POMPES TURBOMOLECULAIRES
TURBOMOLECULAR PUMPS
Manuel utilisateur
User’s manual
Réalisation/Publication: Alcatel Vacuum Technology France - Manuel Utilisateur - Ed 11 - Date : 03/2007 - Référence : 102710 *102710*

Table of Contents

Questions and Answers

  • W
    William WigginsAug 19, 2025
    What to do if the D04 pump temperature exceeds the limit in my Alcatel Vacuum Technology Adixen ATP 400?
    • M
      mbrooksAug 20, 2025
      If the Alcatel Vacuum Technology Water Pump motor temperature exceeds the authorized limit of 85°C, ensure the cooling circuit is functioning correctly. Also, reduce the working pressure or the flow rate. If the problem persists, contact Alcatel Customer Service.
  • D
    David MaddoxAug 22, 2025
    What to do if my Alcatel Vacuum Technology Water Pump is overheating (D21)?
    • C
      Cassandra PriceAug 22, 2025
      If the Alcatel Vacuum Technology Water Pump displays the error 'D21 : PUMP OVERHEAT', verify the pump's cooling system. It might also help to reduce the working pressure or the flow rate.
  • J
    Jonathan HornAug 25, 2025
    What to do if the D03 ACT temperature exceeds the limit in my Alcatel Vacuum Technology Water Pump?
    • S
      salinaschristyAug 25, 2025
      If the Alcatel Vacuum Technology Water Pump controller temperature exceeds the authorized limit (70°C for ACT 600T or 75°C for ACT 200T), check that the cooling circuit is operating correctly. For ACT 600T, verify the internal fan; for ACT 200T, check the ventilation.
  • J
    Joshua WilsonAug 26, 2025
    What to do if my Alcatel Vacuum Technology Water Pump is too hot (D23)?
    • D
      Dr. Michael LaneAug 26, 2025
      If your Alcatel Vacuum Technology Water Pump displays the error 'D23 : HOT PUMP' because the pump temperature exceeds 75°C, first check the pump cooling. Then, reduce the pressure or the flow. Note that if the default is still present, the D21 error appears.
  • H
    Hannah GallegosAug 28, 2025
    What to do if my Alcatel Vacuum Technology Adixen ATP 400 isn’t running?
    • M
      Michele KingAug 28, 2025
      If your Alcatel Vacuum Technology Water Pump isn’t running or the pump is seizing with no messages, manually check the pump rotation. Perform pump maintenance.
  • A
    Aaron JonesAug 30, 2025
    What to do if my Alcatel Vacuum Technology Water Pump controller is overheating (D22)?
    • E
      Emily LeeAug 30, 2025
      If the Alcatel Vacuum Technology Water Pump displays the error 'D22 : CONTROLLER OVERHEAT' and the temperature exceeds 60°C, check the controller cooling circuit, including air admissions and the fan. Additionally, reduce the working pressure or the flow rate.
  • E
    Edward FinleySep 1, 2025
    What does WO3 ACT TEMP mean on my Alcatel Vacuum Technology Adixen ATP 400?
    • M
      Michael DavisSep 1, 2025
      If your Alcatel Vacuum Technology Water Pump displays 'WO3 : ACT TEMP.' because the controller temperature is high (between 60 and 70°C for ACT 600 T or 65 and 75°C for ACT 200 T), check the controller cooling circuit. This includes the internal fan for ACT 600T and the ventilation for ACT 200T.
  • C
    carolinemartinSep 2, 2025
    What does W04 pump temp mean on my Alcatel Vacuum Technology Adixen ATP 400 Water Pump?
    • D
      Donald HowellSep 3, 2025
      If your Alcatel Vacuum Technology Water Pump displays 'W04 : PUMP TEMP.' because the pump temperature is between 75 and 85°C, check the pump ventilation.
  • J
    John MirandaSep 4, 2025
    What does WO1 greasing mean on my Alcatel Vacuum Technology Water Pump?
    • E
      Elizabeth GarciaSep 5, 2025
      If your Alcatel Vacuum Technology Water Pump displays 'WO1 : GREASING' because the authorized limit for ball bearing maintenance time has been reached, regrease the pump and initialize the maintenance counter.
  • N
    Nicole SmithSep 7, 2025
    What does error D07 pump current mean on my Alcatel Vacuum Technology Water Pump?
    • H
      harrisglendaSep 7, 2025
      If the Alcatel Vacuum Technology Water Pump displays the error 'D07 : PUMP CURRENT' due to motor overcurrent or Hall sensor default, reinitialize the controller with the main switch (0/1).

Summary

ATP Series Introduction

Turbomolecular Pump Operating Principle

Explains the fundamental operating mechanism of turbomolecular pumps.

ATP Pump Technical Specifications

Provides detailed specifications and performance data for ATP pumps.

Pump Start-up Procedures

General Safety Instructions

Essential safety guidelines before operating or installing the pump.

Pump Installation and Connections

How to physically connect the pump to the vacuum installation.

ACT 200;600 T Electrical Wiring

Wiring procedures for ACT 200 T and 600 T controllers.

ACT 200;600 T Controller Start-up Guide

Step-by-step guide for starting up ACT 200 T and 600 T controllers.

ACT 1000 T Controller Start-up Guide

Step-by-step guide for starting up the ACT 1000 T controller.

Integrable Controller Functions: Brick;Board Type

OEM Board Controller Functions

Turbomolecular Pump Operation

Initial Pump Start-up and Safety

Initial startup procedures and crucial safety instructions.

Pump Operation in Vacuum Applications

How to operate the pump in a vacuum application.

Pump Maintenance Procedures

Troubleshooting Guide: ACT 200;600 T

Troubleshooting guide for ACT 200 T and 600 T controllers.

Troubleshooting Guide: ACT 1000 T

Troubleshooting guide for the ACT 1000 T controller.

Pump Maintenance Operations

Pre-Maintenance Safety Precautions

Safety measures and precautions before performing maintenance.

ATP 80;100 Bearing Replacement Procedure

Step-by-step guide for replacing bearings in ATP 80/100 pumps.

ATP 150;400;900 Bearing Replacement Procedure

Step-by-step guide for replacing bearings in ATP 150/400/900.

Pump Running-in: ATP 80-400 Models

Running-in procedure for ATP 80, 100, 150, and 400 pumps.

ATP 900 Pump Running-in Procedure

Running-in procedure specifically for the ATP 900 pump.

Maintenance Components

Alcatel Vacuum Technology Adixen ATP 400 Specifications

General IconGeneral
BrandAlcatel Vacuum Technology
ModelAdixen ATP 400
CategoryWater Pump
LanguageEnglish

Related product manuals