Problem Cause Cure
Glass is Dirty 1. Wood is wet Use dry wood
2. Turning down air control Do not turn down until
or damper too soon a) there is a good bed of coals
b) the wood is charred
3. Draft too low Improper chimney height and / or
diameter, -consult dealer
Chimney plugged or restricted,
- inspect and clean
Provide outside air for combustion
4. Door gasket leakage Replace gasket
Check latch for proper operation
Excessive Creosote Buildup See 1,2,3, above. See 1,2,3, above.
Low Heat Output 1. Wood is wet Use dry wood
2. Fire too small Build a larger  re
3. Draft too low Chimney plugged or restricted,
- inspect and clean
Won't Burn Overnight 1. Air control is set too high Set air control lower
2. Not enough wood Unsplit wood is preferred for
overnight burns
3. Draft too high Excessive chimney height and/or
diameter
4. Poor quality or wet wood Use good quality, dry wood
Wood Won't Burn 1. Combustion air supply blocked Check outside air supply for
obstruction
2. Draft too low Chimney plugged or restricted,
-inspect and clean
Chimney oversized or otherwise
unsuitable, -consult Dealer