For Zone 1: 4 1 0 #
For Zone 2: 4 2 0 #
11.3 Door D et ec ti on, Alar m , Acou st i c Si gnal, Door B el l Setti ngs
Toggle mode
Toggle mode
Door Open Detection
Door Open Too Long (DOTL) warning. When used with an optional magnetic contact or built-in magnetic contact
of the lock, if the door is opened normally, but not closed after 1 minute, the inside buzzer will beep automatically
to remind people to close the door and continue for 1 minute before switching off automatically.Door Forced
Open warning. When used with an optional magnetic contact or built- in magnetic
contact of the lock, if the door
is forc ed open, or if the door is opened after 120 seconds of the electro-mechanical lock not closed properly, the
inside buzzer and alarm output will both operate. The
Alarm Output time is adjustable between 1- 3 minutes with
the default being 1 minutes.
To disable door open detection ( Factory default setting )
6 0 #
To enable door open detection
For Zone 1: 6 1 #
For Zone 2: 6 2 #
You can enable the door open detection of only one Zone
Keypad lockout & a larm output options
If there are 10 invalid cards or 10 i ncorrect PIN numbers in a 10 minute period either the keypad will lockout for
10 m inutes or the alarm will operate , depending on the option selected below
Normal status: No keypad lockout or alarm
Keypad Lockout
Alarm output
Keypad Tone
The keypad tone can be set on or off. When on, the device will give the voice when press
the keys; when off, the
device will be in silent
Alarm Output time
To set the alarm output time(1~ 3 minutes)Factory
defaul is 1 minute
7 0 # ( Factory default setting)
7 0 #
7 2 # (Alarm output time:1 minute)
8 1 ~ 3 #