EasyManua.ls Logo

Alfa Laval ALP 15-85 - User Manual

Alfa Laval ALP 15-85
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Marine & Diesel Equipment
Oil Feed Pumps ALP 15-85
X027351A
Product No.
Printed
Book No.
Jan 2020
9006009-02 V13
Component
Description

Questions and Answers

  • V
    Veronica RogersAug 19, 2025
    What to do if Alfa Laval Water Pump pressure relief valve leaks?
    • S
      Stanley MillerAug 19, 2025
      If your Alfa Laval Water Pump's pressure relief valve is leaking, try cleaning the valve and reseating it if necessary.
  • J
    jfoxAug 21, 2025
    How to decrease viscosity in Alfa Laval Water Pump?
    • S
      sjohnsonAug 21, 2025
      If the viscosity of the liquid being pumped is too high, you can increase the temperature of the liquid or reduce the rotation speed of your Alfa Laval Water Pump.
  • M
    Meagan MeyerAug 23, 2025
    How to fix resonance in Alfa Laval Water Pump system?
    • J
      John RoseAug 25, 2025
      To fix resonance in the Alfa Laval Water Pump system, consider providing a flexible bearing arrangement for the pump unit or making the connections with hoses.
  • J
    Jonathan VaughanAug 26, 2025
    What to do if there are foreign bodies in Alfa Laval ALP 15-85 Water Pump?
    • M
      Mary WaltersAug 26, 2025
      If you have foreign bodies in the Alfa Laval Water Pump, dismantle the pump and clean it. Smooth any superficial damage to the housing and rotating parts with an oilstone. If necessary, replace the pump.
  • J
    Jennifer StewartAug 28, 2025
    What to do if Alfa Laval Water Pump suction pipe is closed?
    • D
      Dr. Marissa MarquezAug 28, 2025
      If the pump suction pipe is closed, check the shut-off devices in the suction pipe and open them, if necessary.
  • D
    dustinjonesAug 30, 2025
    How to fix high suction head in Alfa Laval ALP 15-85 Water Pump?
    • J
      Juan GarrettAug 30, 2025
      If the suction head is too high for your Alfa Laval Water Pump, reinstall the pump at a lower suction head level. You can also reduce the pipe length, increase the pipe diameter, heat the liquid to reduce viscosity, or check that the strainer is not clogged.
  • C
    cooperpaulSep 2, 2025
    What to do if Alfa Laval Water Pump intake container level is too low?
    • B
      blakemorganSep 2, 2025
      If the level of liquid in the intake container is too low, top up the pumped liquid for your Alfa Laval Water Pump.
  • L
    Lee RamirezSep 4, 2025
    What to do if Alfa Laval Water Pump viscosity is too low?
    • K
      Kristine RamosSep 4, 2025
      If the viscosity of the pumped liquid is too low, decrease the temperature of the liquid.
  • D
    Dakota JohnsonSep 6, 2025
    How to remove airlock in Alfa Laval ALP 15-85?
    • N
      ndiazSep 6, 2025
      If there is an airlock or gas in the liquid of your Alfa Laval Water Pump, increase the rotation speed. Also, test the pipe system for ingress of air and replace parts if necessary, reduce the suction head, or increase the inlet pressure.
  • E
    Emily CollinsSep 8, 2025
    How to prevent wear of sealing surfaces in Alfa Laval Water Pump?
    • C
      Christine CabreraSep 8, 2025
      To prevent advanced wear of sealing surfaces in your Alfa Laval Water Pump, support the weight of the pipe system.

Summary

EC Declaration of Conformity

Warning Signs

Warning signs

Definitions of warning grades (Danger, Warning, Caution, Note) used in the text.

Function Description

Application

Explains the intended use and limitations of the pump.

Design

Describes the internal construction and working principle of screw pumps.

Parts

Lists and identifies the individual parts of the pump.

Fault Finding

Possible faults

Lists common faults and their potential causes/remedies.

Troubleshooting

Provides step-by-step guidance for diagnosing and resolving pump issues.

Maintenance

Safety instructions on maintenance and repairs

Outlines essential safety precautions for performing maintenance work.

Required maintenance

Details checks and actions needed for regular pump maintenance.

Replacing the elastomer coupling

Step-by-step guide for removing and installing the elastomer coupling.

Replacing the mechanical seal and ball bearing

Detailed procedures for replacing the mechanical seal and ball bearing.

Technical Data

Operating limits

Lists the maximum and minimum operating parameters for the pump.

Required Net Positive Suction Height (NPSH) values

Provides NPSH values for various conditions to prevent cavitation.

Dimensions

Provides detailed dimensional drawings and specifications for the pump and unit.

Capacity tables

Contains tables detailing pump capacity under various conditions and frequencies.

Installation

Installing the pump

Provides guidelines and demands for mounting the pump in its operational location.

Protect the pump against contamination

Instructions on preventing impurities from entering the pump during installation.

Piping

Requirements and guidelines for pipe installation, support, and connection.

Commissioning

Procedures for preparing and starting the pump for operation.

Transportation, storage and disposal

Lifting the pump;pump unit

Safety precautions and methods for lifting the pump or pump unit.

Storage

Guidelines for storing the pump, including preservation methods.

Disposing of the pump

Guidelines for the environmentally responsible disposal of the pump.

Spare parts

Spare part kits

Lists available spare part kits and their corresponding part numbers.

Tightening torques

Provides torque specifications for various screws used in assembly and maintenance.

Alfa Laval ALP 15-85 Specifications

General IconGeneral
TypeCentrifugal pump
Speed2900 rpm
Liquid temperature+120 °C
Flow Rate15 m³/h
Inlet Diameter40 mm
Outlet Diameter32 mm
Operating Temperature+120°C

Related product manuals