5 Mainten ance
5.2 Cleaning Procedure
C
l
e
a
n
i
n
g
p
r
o
c
e
d
u
r
e
f
o
r
s
o
i
l
e
d
i
m
p
e
l
l
e
r
s
c
r
e
w
t
a
p
p
e
d
h
o
l
e
:
W
a
r
n
i
n
g
:
Always follow the instructions in the safety data sheet for the cleaning agent.
1. Remove stub shaft (7) as per section 4 of the Service manual.
2. Submerge and soak the stub shaft for 5 minutes in COP tank with 2% caustic wash
3. Scrub the blind tapped impeller screw hole vigorously by plunging a clean 1/2” diameter sanitary bristle pipe brush in and out
of the hole for two minutes while submerged.
4. Soak stub shaft (7) in acid sanitiser for 5 minutes, then scrub blind tapped hole as described in step 3 above.
5. Rinse well with clean water and blow-dry blind tapped hole with clean air.
6. Swab test the inside o f the tapped hole to determine cleanliness.
7. Should the swab test fail, repeat steps 2 to 6 above until the swab test is passed.
Should swab testing continue to fail, or time is of the essence, install a new (spare) stub shaft (7).