18
Electrical Service
The ZIMMER
vaporizer is manufactured as an explosion proof
device suitable for hazardous locations. Do not separate the heat
exchanger to access the electrical enclosure separating the
enclosure will void warranty!
When connecting the electrical service for the ZIMMER
you will
need a circuit breaker appropriate for the application. See
Electrical Specifications in the Appendix.
You will also need a disconnect switch located within sight of
the vaporizer (refer to Electrical Specification in Appendix).
Select the appropriate size conductors based on the current
draw (refer to Electrical Specification in Appendix) and
conductor run distance (see reference charts below).
Install metal terminal box to the ¾” MNPT seal-off to make the
wiring connections in accordance with the local electrical codes.
Ensure the terminal box is connected to seal-off before
vaporizer is mounted to wall.
Metal Terminal Box (3/4”) for 50kg/hr and Smaller models
Use a suitably certified metal terminal box for the area
classification, ATEX or IECEx certified - for Europe; or Class I,
Division 1, Group D (UL listed or equivalent) - for US and
Canada. Electrical components must be rated for 130°C
(266°F). (ASDI P/N 80895 (CLASS I DIV 1) OR 80896 (ATEX
Ex d)
Metal Terminal Box (1-1/4”) for 100kg/hr and 150kg/hr models
Ex db IIA Gb or Ex eb IIA Gb, ATEX or IECEx certified - for
Europe; or Class I, Division 1, Group D (UL listed or equivalent)
- for US and Canada. Electrical components must be rated for
130°C (266°F). (KILLARK P/N GESLT-4 or equivalent)
Do not separate vaporizer sections to access the wiring. Use
conductor assembly provided.
Connect the green conductor to ground. See appropriate wiring
schematic in Appendix based on your desired installation. Do
not pull on, twist, or bend the wires.
CAUTION________________________________________
When installing the metal terminal box, use an open-end wrench to
securely hold the factory provided seal-off to prevent twisting!
___________________________________________________