A-10 Parameter List/Record
Table A.I Trend Buffer #3 Parameters
Table A.J Trend Buffer #4 Parameters
Table A.K Node Adapter Parameters
Description
Parameter
Number Parameter Range Parameter Value
Trend Buffer #3 is linked to parameter:
The output of trend buffer #3 is linked to parameter:
Trend 3 operand parameter X 930 1-947
Trend 3 operand parameter Y 931 1-947
Trend 3 operator 932 GT, LT, EQ, AND, NAND, OR, NOR
Trend 3 sample rate 933 0.0004-30 seconds
Trend 3 post samples 934 0-99
Trend 3 multiple trigger 935 OFF, ON
Trend 3 enable 936 OFF, ON
Trend 3 output rate 937 0.0004-30 seconds
Description
Parameter
Number Parameter Range Parameter Value
Trend Buffer #4 is linked to parameter:
The output of trend buffer #4 is linked to parameter:
Trend 4 operand parameter X 940 1-947
Trend 4 operand parameter Y 941 1-947
Trend 4 operator 942 GT, LT, EQ, AND, NAND, OR, NOR
Trend 4 sample rate 943 0.0004-30 seconds
Trend 4 post samples 944 0-99
Trend 4 multiple trigger 945 OFF, ON
Trend 4 enable 946 OFF, ON
Trend 4 output rate 947 0.0004-30 seconds
PLC I/O Word Port/Parameter A/B
Linked to
Parameter Description
Node Adapter Configuration Rack #
O : 0R0 Block Transfer
O : 0R1 400/300
O : 0R2 401/301
O : 0R3 402/302
O : 0R4 403/303
O : 0R5 404/304
O : 0R6 405/305
O : 0R7 406/306
I : 0R0 Node Adapter Status
I : 0R1 450/350
I : 0R2 451/351
I : 0R3 452/352
I : 0R4 453/353
I : 0R5 454/354
I : 0R6 455/355
I : 0R7 456/356